English
Language : 

C504 Datasheet, PDF (41/49 Pages) Siemens Semiconductor Group – 8-Bit CMOS Microcontroller
C504
AC Characteristics for C504-L24 / C504-2R24
VCC = 5 V + 10 %, – 15 %; VSS = 0 V
TA = 0 to 70 °C
for the SAB-C504
TA = – 40 to 85 °C
for the SAF-C504
(CL for port 0, ALE and PSEN outputs = 100 pF; CL for all other outputs = 80 pF)
Program Memory Characteristics
Parameter
ALE pulse width
Address setup to ALE
Address hold after ALE
ALE low to valid instr in
ALE to PSEN
PSEN pulse width
PSEN to valid instr in
Input instruction hold after PSEN
Input instruction float after PSEN
Address valid after PSEN
Address to valid instr in
Address float to PSEN
Symbol
Limit Values
24-MHz clock
Variable Clock
1/tCLCL = 3.5 MHz to
24 MHz
min. max. min.
max.
tLHLL
43
tAVLL
17
tLLAX
17
tLLIV
–
tLLPL
22
tPLPH
95
tPLIV
–
tPXIX
0
t *)
PXIZ
–
t *)
PXAV
37
tAVIV
–
tAZPL
0
–
2tCLCL – 40 –
–
tCLCL – 25 –
–
tCLCL – 25 –
80 –
4tCLCL – 87
–
tCLCL – 20 –
–
3tCLCL – 30 –
60 –
3tCLCL – 65
–
0
–
32 –
–
tCLCL – 5
148 –
–
0
tCLCL – 10
–
5tCLCL – 60
–
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
*) Interfacing the C504 to devices with float times up to 37 ns is permissible. This limited bus contention will not
cause any damage to port 0 drivers.
Semiconductor Group
41