English
Language : 

S112S01 Datasheet, PDF (4/5 Pages) Sharp Electrionic Components – SIP Type SSR for Medium Power Control
Fig. 5 Forward Current vs. Forward Voltage
100
Ta = 100˚C
50
75˚C
50˚C
20
10
5
25˚C
0˚C
- 25˚C
2
1
0
1.0
2.0
Forward voltage VF (V)
Fig. 7 Maximum ON-state Power Dissipation vs.
RMS ON-state Current
(S112S01Series )
20
Ta = 25˚C
18
16
14
12
10
8
6
4
2
0
0 2 4 6 8 10 12 14 16
RMS ON-state current I T ( Arms )
Fig. 9 Minimum Trigger Current vs.
Ambient Temperature
10
( ) VD = 12V S112S01, S212S01
S116S01,S216S01
8
( ) VD = 6V S112S02,S212S02
S116S02,S216S02
RL= 30Ω
6
S112S01/S212S01
4 S116S01/S216S01
2
S112S02/S212S02
S116S02/S216S02
0
- 25
0
25
50
75
100
Ambient temperature T a (˚C)
S112S01 Series/S116S01 Series
Fig. 6 Surge Current vs. Power-on Cycle
200
180
f= 60H z
Tj = 25˚C Start
160
140
120
S116S01Series
100
80
S112S01Series
60
40
20
0
1
2
5 10 20
50 100
Power-on cycle (Times)
Fig. 8 Maximum ON-state Power
Dissipation vs. RMS ON-state Current
(S116S01Series)
20
18 Ta = 25˚C
16
14
12
10
8
6
4
2
0
0 2 4 6 8 10 12 14 16
RMS ON-state current I T ( Arms )
Fig.10 Repetitive Peak OFF-state Current vs.
Ambient Temperature
( S112S01/ S112S02/S116S01/ S116S02)
10 - 4
VD = 400V
10 - 5
10 - 6
10 - 7
10 - 8
S112S02
S116S02
S112S01
S116S01
10 - 9
- 25
0
25
50
75
100
Ambient temperature T a (˚C)