English
Language : 

S112S01 Datasheet, PDF (1/5 Pages) Sharp Electrionic Components – SIP Type SSR for Medium Power Control
S112S01 Series
S116S01 Series
s Features
1. Compact, high radiation resin
mold package
2. RMS ON-state current
S112S01 Series : 12Arms at TC <= 70˚C
( With heat sink)
S116S01 Series : 16Arms at TC <= 60˚C
( With heat sink)
3. Built-in zero-cross circuit
(S112S02 / S212S02 / S116S02 / S216S02 )
4. High repetitive peak OFF-state voltage
S112S01 / S112S02 / S116S01 / S116S02
VDRM : 400V
S212S01 / S212S02 / S216S01 / S216S02
VDRM : 600V
5. Isolation voltage between input and output
(Viso : 4 000Vrms )
6. Recognized by UL, file No. E94758
S112S01 / S112S02
S116S01 / S116S02
7. Approved by CSA, No. 63705
S112S01 / S112S02
S116S01 / S116S02
s Applications
1. Copiers, laser beam printers
2. Automatic vending machines
3. FA equipment
S112S01 Series/S116S01 Series
SIP Type SSR for Medium
Power Control
s Outline Dimensions
(Unit : mm )
* The metal parts marked*
are common to terminal 1 .
g Do not allow external connection.
( ) : Typical dimensions
A (Model No.)
B
S112S01
12A125VAC
S112S02
S116S01
16A125VAC
S116S02
S212S01
S212S02 12A250VAC
S216S01
16A250VAC
S216S02
18.5 ± 0.2
16.4 ± 0.3
φ 3.2 ± 0.2
*
5.5 ± 0.2
A
4 - 1.1 ± 0.2
4 - 1.25 ± 0.3
4 - 0.8 ± 0.2
B
+-
1 23 4
(5.08) (7.62)
Internal connection diagram
S112S01/S116S01
S212S01/S216S01
(2.54)
0.6 ± 0.1 (1.4)
S112S02/S116S02
S212S02/S216S02
Zero-cross
circuit
1 2 34
1 Output (Triac T2)
2 Output (Triac T1)
3 Input ( + )
4 Input ( - )
12
34
1 Output (Triac T2)
2 Output (Triac T1)
3 Input ( + )
4 Input ( - )
s Model line-ups
For phase control
No built-in zero-cross circuit
Built-in zero-cross circuit
For 100V
lines
S112S01
S116S01
S112S02
S116S02
For 200V
lines
S212S01
S216S01
S212S02
S216S02
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”