English
Language : 

LQ035Q7DH06 Datasheet, PDF (21/26 Pages) Sharp Electrionic Components – TFT-LCD Module
LCP-05020-18
(13) Handling Precautions
13-1) Insertion and taking out of FPCs
Be sure insert and take out of the FPC into the connector of the set after turning off the power
supply on the set side.
13-2) Handling of FPCs
The FPC for LCD panel shall be bent only slit portion. The bending slit shall be bent uniformly
on the whole slit portion with bending radius larger than 0.6mm ,and only inner side (back side
of the module). Don’t bend it outer side (display surface side).
Don’t give the FPCs too large force, for example, hanging the module with holding FPC.
13-3) Installation of the module
On mounting the module, be sure to fix the module on the same plane. Taking care not to warp or
twist the module.
13-4) Precautions when mounting
(1) If water droplets and oil attaches to it for a long time, discoloration and staining occurs. Wipe them off
immediately.
(2) Glass is used for the TFT-LCD panel. If it is dropped or bumped against a hard object, it may be broken.
Handle it with sufficient care.
(3) As the CMOS IC is used in this module, pay attention to static electricity when handling it. Take a
measure for grounding on the human body.
13-5) Others
(1) The liquid-crystal is deteriorated by ultraviolet rays. Do not leave it in direct sunlight and strong
ultraviolet rays for many hours.
(2) If it is kept at a temperature below the rated storage temperature, it becomes coagulated and the panel
may be broken. Also, if it is kept at a temperature above the rated storage temperature, it becomes
isotropic liquid and does not return to its original state. Therefore, it is desirable to keep it at room
temperature as much as possible.
(3) If the LCD breaks, don’t put internal liquid crystal into the mouth. When the liquid crystal sticks to the
hands, feet and clothes, wash it out immediately.
(4) Wipe off water drop or finger grease immediately. Long contact with water may cause discoloration or
spots.
(5) Observe general precautions for all electronic components.
(6) VCOM must be adjusted on condition of your final product. No adjustment causes the deterioration for
display quality.
(7) Static image should not be displayed more than 5 minutes in order to prevent from occurrence of
residual image.
(8) If local pressure joins T/P surface for a long time, it will become the cause of generating of Newton’s ring.