PERFORMANCE CHARACTERISTICS (VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
RVAP150GU...
Operating pressure
Zero pressure offset
Span4
Full scale output
Thermal effects3
Characteristics
Offset
Span
Combined offset and span
Total accuracy5
Non-linearity (BSL)2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
-45 to +125°C
Min.
0
0.46
3.93
Typ.
0.50
4.0
4.5
±0.15
±0.25
1
RVAP250GU...
Operating pressure
Zero pressure offset
Span4
Full scale output
Thermal effects3
Characteristics
Offset
Span
Combined offset and span
Non-linearity (BSL)2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
Min.
0
0.46
3.93
Typ.
0.50
4.0
4.5
±0.15
±0.25
1
Max.
150
0.54
4.07
±0.75
±1.0
±1.5
±0.75
±1.0
±1.5
±0.75
±1.0
±1.5
±2.5
±0.1
10.0
Max.
250
0.54
4.07
±0.75
±1.0
±2.0
±0.75
±1.0
±2.0
±0.75
±1.0
±3.0
±0.1
10.0
Unit
psig
V
%FSS
mA
ms
Unit
psig
V
%FSS
mA
ms
E / 11701 / A
6/8