RVA Series
Fully signal conditioned pressure transducers
PERFORMANCE CHARACTERISTICS (VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
RVAP030GU...
Operating pressure
Zero pressure offset
Span4
Full scale output
Thermal effects3
Characteristics
Offset
Span
Combined offset and span
Non-linearity (BSL)2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +125°C
Min.
0
0.46
3.92
Typ.
0.50
4.00
4.5
±0.15
±0.25
1
Max.
30
0.54
4.08
±1.5
±2.0
±2.25
±1.5
±2.0
±2.25
±2.0
±2.25
±0.3
10.0
Unit
psig
V
%FSS
mA
ms
RVAP100GU...
Operating pressure
Zero pressure offset
Span4
Full scale output
Thermal effects3
Characteristics
Offset
Span
Combined offset and span
Non-linearity (BSL)2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
Min.
0
0.46
3.91
Typ.
0.50
4.0
4.5
±0.15
±0.25
1
Max.
100
0.54
4.09
Unit
psig
V
±1.25
±2.0
±3.0
±0.75
±1.0
±2.0
±1.5
±2.5
±3.0
±0.1
%FSS
10.0
mA
ms
E / 11701 / A
5/8
www.sensortechnics.com