English
Language : 

RVAQ050GB1 Datasheet, PDF (4/8 Pages) Sensortechnics GmbH – Fully signal conditioned pressure transducers
RVA Series
Fully signal conditioned pressure transducers
PERFORMANCE CHARACTERISTICS (VS = 5.00 V, RL > 100 kW, tamb = 25°C)
RVAP015GU...
Operating pressure
Zero pressure offset
Span4
Full scale output
Thermal effects3
Characteristics
Offset
Span
Combined offset and span
Total accuracy5
Non-linearity (BSL)2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
-18 to +63°C
-45 to +85°C
-18 to +63°C
-45 to +85°C
-18 to +63°C
-45 to +85°C
-45 to +85°C
Min.
0
0.39
3.89
Typ.
0.50
4.00
4.5
±0.15
±0.25
1
Max.
15
0.61
4.11
±2.0
±2.75
±0.75
±1.0
±2.0
±3.0
±4.0
±0.2
10.0
Unit
psig
V
%FSS
mA
ms
RVAP015GV...
Operating pressure
Zero pressure offset
Span4
Full scale output
Thermal effects3
Characteristics
Offset
Span
Combined offset and span
Total accuracy5
Non-linearity (BSL)2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
-18 to +25°C
-45 to +85°C
-18 to +25°C
+25 to +85°C
-45 to +25°C
-18 to +25°C
+25 to +85°C
-40 to +25°C
+45 to +85°C
Min.
0
0.46
3.9
Typ.
0.50
4.0
4.5
±0.15
±0.25
1
Max.
-15
0.54
4.1
Unit
psig
V
±0.75
±1.0
±2.0
±1.25
±2.25
±1.5
±1.0
±1.75
±2.25
±0.3
%FSS
10.0
mA
ms
E / 11701 / A
4/8
www.sensortechnics.com