Typical Characteristics (continued)
1.2
1.1
1.0
0.9
0.8
-100
 Note :
1. VGS = 0 V
2. ID = 250PA
-50
0
50
100
150
200
T , Junction Temperature [oC]
J
Figure 7. Breakdown Voltage Variation
vs Temperature
103
Operation in This Area
is Limited by R DS(on)
100 Ps
102
1 ms
10 ms
101
DC
100
10-1
10-2
10-1
* Notes :
1. TC = 25 oC
2. T = 175 oC
J
3. Single Pulse
100
101
102
VDS, Drain-Source Voltage [V]
Figure 9. Maximum Safe Operating Area
2.5
2.0
1.5
1.0
0.5
0.0
-100
Note :
1. VGS = 10 V
2. I = 30 A
D
-50
0
50
100
150
200
TJ, Junction Temperature [oC]
Figure 8. On-Resistance Variation
vs Temperature
70
60
50
40
30
20
10
0
25
50
75
100
125
150
175
TC, Case Temperature [oC]
Figure 10. Maximum Drain Current
vs Case Temperature
100
D=0.5
0.2
10-1
0.1
0.05
0.02
0.01
10-2
10-5
* Notes :
1. ZTJC(t) = 1.1 oC/W Max.
2. Duty Factor, D=t /t
12
3. TJM - TC = PDM * ZTJC(t)
single pulse
PDM
t1
t2
10-4
10-3
10-2
10-1
100
101
t1, Square Wave Pulse Duration [sec]
Figure 11. Transient Thermal Response Curve