LA8518NM
— Address chart —
Output
LINE
HAND
RF1
RF2
DOOR
AUX
PWR
PRE
LINE
HAND
RF1
—
01
02
07
—
08
0D
0E
—
14
15
16
—
1B
1C
21
22
23
29
—
2A
2F
30
31
Input
RF2
DOOR
AUX
03
—
04
09
0A
0B
0F
10
11
—
17
18
1D
—
1E
24
25
26
2B
2C
2D
32
33
34
MIC
OGM
PRE
05
06
—
—
0C
—
12
13
—
19
1A
—
1F
20
—
27
28
—
—
2E
37
35
36
—
Other Control Switches
00 All crosspoint switches and control switches off *2
38 Mixing switch for PB amplifier-OGM amplifier on
39 Transmitting/receiving CTL (SW1 and SW2 in the block diagram) *1
3A Receiver amplifier ATT
Set to 0 dB
3B Line amplifier ATT
Set to –6 dB
3C ALC on
3D PB amplifier on
3E REC amplifier on
3F Power amplifier on
40 Electronic volume control
0 dB
41 Electronic volume control
–4dB
42 Electronic volume control
–8dB
43 Electronic volume control
–12dB
*2
44 Electronic volume control
–16dB
45 Electronic volume control
–20dB
46 Electronic volume control
–24dB
47 Electronic volume control
–28dB
*1: When address 39 is on, SW1 enables the transmitting amplifier output (pin 58) signal, and SW4 enables the receiving
amplifier output (pin 7) or KT (pin 55) signal. If voltage is not supplied to pin 31 (VCC) (power is off), the status of SW1
and SW4 is the same as address 39 is in on state.
*2: When setting address 00 and 40 to 47, ‘‘D’’ data may be either ‘‘0’’ or ‘‘1’’.
Note 1: The receiver amplifier ATT is set to −6 dB when power is first applied, when a reset is performed, and when all of the
switches are off.
Note 2: The line amplifier ATT is set to 0 dB when power is first applied, when a reset is performed, and when all of the switches
are off.
Note 3: The electronic volume control is set to 0 dB when power is first applied, when a reset is performed, and when all of the
switches are off.
Note 4: The addresses are given in hexadecimal notation.
No.5421-9/31