English
Language : 

RGT16NS65D Datasheet, PDF (9/12 Pages) Rohm – 650V 8A Field Stop Trench IGBT
RGT16NS65D
lElectrical Characteristic Curves
Data Sheet
Fig.17 Typical Diode Forward Current
vs. Forward Voltage
24
20
16
12
8
Tj= 175ºC
4
Tj= 25ºC
0
0 0.5 1 1.5 2 2.5 3
Forward Voltage : VF[V]
Fig.18 Typical Diode Reverse Recovery Time
vs. Forward Current
160
140
120
100
Tj= 175ºC
80
60
40
20
Tj= 25ºC
0
0
2
4
VCC=400V
diF/dt=200A/µs
Inductive load
6
8
10
Forward Current : IF [A]
Fig.19 Typical Diode Reverse Recovery Current
vs. Forward Current
14
12
10
Tj= 175ºC
8
6
4
Tj= 25ºC
2
0
0
5
VCC=400V
diF/dt=200A/µs
Inductive load
10
15
20
Forward Current : IF [A]
Fig.20 Typical Diode Reverse Recovery Charge
vs. Forward Current
0.7
VCC=400V
0.6
diF/dt=200A/µs
Inductive load
0.5
0.4
Tj= 175ºC
0.3
0.2
Tj= 25ºC
0.1
0
0
5
10
15
20
Forward Current : IF [A]
www.rohm.com
© 2014 ROHM Co., Ltd. All rights reserved.
9/11
2014.05 - Rev.A