English
Language : 

BU9832GUL-W_12 Datasheet, PDF (3/30 Pages) Rohm – WLCSP EEPROM
BU9832GUL-W (8Kbit)
Datasheet
●Operating timing characteristics
(Ta=-40℃ to +85℃, unless otherwise specified, load capacity CL1=100pF)
Parameter
Symbol
1.8≤Vcc≺ 2.5V
Min. Typ. Max.
SCK frequency
fSCK
–
–
2
SCK high time
tSCKWH 200
–
–
SCK low time
tSCKWL 200
–
–
CS high time
tCS
200
–
–
CS setup time
tCSS
200
–
–
CS hold time
tCSH
200
–
–
SCK setup time
tSCKS
200
–
–
SCK hold time
tSCKH
200
–
–
SI setup time
tDIS
40
–
–
SI hold time
tDIH
50
–
–
Data output delay time1
tPD1
–
–
150
Data output delay time2 (CL2=30pF)
Output hold time
tPD2
–
–
145
tOH
0
–
–
Output disable time
tOZ
–
–
250
HOLD setting setup time
tHFS
120
–
–
HOLD setting hold time
tHFH
90
–
–
HOLD release setup time
tHRS
120
–
–
HOLD release hold time
tHRH
140
–
–
Time from HOLD to output High-Z
tHOZ
–
–
250
Time from HOLD To output change
SCK rise time
*1
SCK fall time
*1
Output rise time
*1
Output fall time
*1
tHPD
–
–
150
tRC
–
–
1
tFC
–
–
1
tRO
–
–
100
tFO
–
–
100
Write time
*1 NOT 100% TESTED
tE/W
–
–
5
2.5≤Vcc≺ 5.5V
Min. Typ. Max.
–
–
5
85
–
–
85
–
–
85
–
–
90
–
–
85
–
–
90
–
–
90
–
–
20
–
–
40
–
–
–
–
70
–
–
55
0
–
–
–
–
100
60
–
–
40
–
–
60
–
–
70
–
–
–
–
100
–
–
70
–
–
1
–
–
1
–
–
50
–
–
50
–
–
5
Unit
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
µs
ns
ns
ms
●AC measurement conditions
Parameter
Load capacity 1
Load capacity 2
Input rise time
Input fall time
Input voltage
Input / Output judgment voltage
Symbol
CL1
CL2
–
–
–
–
Limits
Unit
Min. Typ. Max.
–
–
100 pF
–
–
30
pF
–
–
50
ns
–
–
50
ns
0.2Vcc/0.8Vcc
V
0.3Vcc/0.7Vcc
V
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
3/26
TSZ02201-0R2R0G100410-1-2
30.AUG.2012 Rev.001