English
Language : 

M16C5LD_15 Datasheet, PDF (80/88 Pages) Renesas Technology Corp – RENESAS MCU
M16C/5LD Group, M16C/56D Group
5. Electrical Characteristics
Timing Requirements
(VCC = 3 V, VSS = 0 V, at Topr = −40°C to 85°C unless otherwise specified)
VCC = 3 V
Table 5.37 Timer A Input (Two-Phase Pulse Input in Event Counter Mode)
Symbol
tc(TA)
tsu(TAIN-TAOUT)
tsu(TAOUT-TAIN)
Parameter
TAiIN input cycle time
TAiOUT input setup time
TAiIN input setup time
Standard
Unit
Min.
Max.
2
μs
500
ns
500
ns
Two-phase pulse input in event counter mode
tc(TA)
TAiIN input
TAiOUT input
tsu(TAIN-TAOUT)
tsu(TAIN-TAOUT)
tsu(TAOUT-TAIN)
tsu(TAOUT-TAIN)
Figure 5.18 Timer A Input (Two-Phase Pulse Input in Event Counter Mode)
R01DS0132EJ0120 Rev.1.20
Nov 25, 2011
Page 80 of 84