English
Language : 

H8S-2172 Datasheet, PDF (562/570 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family H8S-2100 Series
Item
Figure 18.29 VCL
Capacitor Connection
Method
Page Revisions (See Manual for Details)
522 Figure 18.29 amended
An external capacitor to
stabilize the internal voltage
One 0.1-µF capacitor
VCL
VSS
VDo not connect the Vcc power-supply to the VCL pin.
If connected, the LSI may be permanently damaged.
Connect the VCC power-Supply to the other Vcc pin in the usual way.
Use a multilayer ceramic capacitor (one 0.1-µF capacitor) for this circuit,
and place it/them near the VCL pin.
Rev. 2.00, 03/04, page 530 of 534