M306V8FJFP Datasheet, PDF (335/365 Pages) Renesas Technology Corp – SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER | |||
|
◁ |
M306V8FJFP
Block Erase
Write âxx2016â in the first bus cycle and write âxxD016â to the uppermost address of a block (even
address, however) in the second bus cycle, and an auto erase operation (erase and verify) will start.
Check the FMR0 registerâs FMR00 bit to see if auto erasing has finished.
The FMR00 bit is â0â (busy) during auto erasing and set to â1" (ready) when auto erasing is completed.
Check the FMR0 registerâs FMR07 bit after auto erasing has finished, and the result of auto erasing
can be known. (Refer to âFull Status Check.â)
Figure 19.10 shows an example of a block erase flowchart.
Each block can be protected against erasing by a lock bit. (Refer to âData Protect Function.â)
Writing over already programmed addresses is inhibited.
In EW1 mode, do not execute this command on any address at which the rewrite control program is
located.
In EW0 mode, the microcomputer goes to read status register mode at the same time auto erasing
starts, making it possible to read the status register. The status register bit 7 (SR7) is cleared to â0â at
the same time auto erasing starts, and set back to â1â when auto erasing finishes. In this case, the
microcomputer remains in read status register mode until the Read Array or Read Lock Bit Status
command is written next.
Start
Write the command code âxx2016â
Write âxxD016â to the uppermost
block address
NO
FMR00=1?
YES
Full status check
Block erase completed
Note: Write the command code and data at even number.
Figure 19.10. Block Erase Command
Rev.1.31 Apr 18, 2005 page 335 of 363
REJ03B0082-0131
|
▷ |