6. E8a Emulator Functions (Supplement on the User’s Manual)
(2) Event B
Set the contents of the Event B. You can set the conditions of the address comparison with mask specification for
the Event B.
Table 6.3 Contents of the Event B
Option
Description
Address (with mask specification) Same as the Event A.
Access Size
Same as the Event A.
Access Type
Same as the Event A.
(3) Break Condition
Set the break condition.
Table 6.4 Break Condition
Option
Description
Break
Break at Trace Full
Select a break condition.
- None: None specified. (No break by event)
- Event A: Breaks the program when the Event A is encountered.
- Event A or B: Breaks the program when either the Event A or Event B is
encountered.
- Event A and B: Breaks the program when both the Event A and Event B are
encountered.
- Event B->A: Breaks the program when an event is encountered in the order of the
Event B and Event A.
Check it to break the program when the trace buffer is filled. It can be set with the break
condition by event.
(4) Trace Condition
Set the trace condition.
Table 6.5
Option
Type
Start
Stop
Pick up
Trace Condition
Description
Select a trace type.
- Branch Trace
- Data Trace
Select a start condition for the trace measurement.
- Go: Starts a measurement when starting executing the target program.
- Event A: Starts a measurement when the Event A is encountered.
- Event A or B: Starts a measurement when either the Event A or Event B is encountered.
- Event A and B: Starts a measurement when both the Event A and Event B are encountered.
- Event B->A: Starts a measurement when an event is encountered in the order of the Event B
and Event A.
Select a stop condition for the trace measurement.
- Break: Stops a measurement when stopping executing the target program.
- Trace FULL: Stops a measurement when the trace data is filled.
- Event A: Stops a measurement when the Event A is encountered.
- Event A or B: Stops a measurement when either the Event A or Event B is encountered.
- Event A and B: Stops a measurement when both the Event A and Event B are encountered.
- Event B->A: Stops a measurement when an event is encountered in the order of the Event B
and Event A.
Select an event to record when tracing data.
- Event A: Records only data access which encounters the condition of the Event A.
- Event A or B: Records only data access which encounters the condition of either the Event A
or Event B.