English
Language : 

E1 Datasheet, PDF (15/50 Pages) Renesas Technology Corp – E1/E20 Emulator
E1/E20 Emulator
Designing the User System
Table 2.5 38-Pin Connector Pin Assignments in JTAG Interface Connection (for RX610, RX621, RX62N,
RX62T and RX62G Groups)
Pin
No.
Signal *1
Direction
*2
Note
Pin
No.
Signal *1
Direction
*2
Note
1 NC
–
Not connected
2 (MD0)
*5
I/O
Operation mode
3 (EMLE) *4
I/O
4 NC
–
Not connected
5 GND
*3
–
Checking
6 TRCLK
Output
connection to
user system
7 NC
–
Not connected
8 (MD1)
*5
I/O
Operation mode
9 RES#
I/O
User system
10 NC
–
Not connected
reset
11 TDO
Output
12 VCC
–
Power supply
13 NC
–
Not connected
14 VCC
–
Power supply
15 TCK
Input Communication 16 NC
–
Not connected
clock
17 TMS
Input
18 NC
–
Not connected
19 TDI
Input
20 NC
–
Not connected
21 TRST#
Input
22 NC
–
Not connected
23 NC
–
Not connected
24 TRDATA3
Output
25 NC
–
Not connected
26 TRDATA2
Output
27 NC
–
Not connected
28 TRDATA1
Output
29 NC
–
Not connected
30 TRDATA0
Output
31 NC
–
Not connected
32 TRSYNC
Output
33 NC
–
Not connected
34 NC
–
Not connected
35 NC
–
Not connected
36 NC
–
Not connected
37 NC
–
Not connected
38 NC
–
Not connected
Notes: 1. These are the names of the MCU pins at the time the E1 or E20 is connected (i.e. during
debugging).
2. Input to or output from the user system.
3. Securely connect pin 5 and the GND bus lead of the connector to GND on the user system.
These are used as electrical GND and for the E1 or E20 to monitor connection to the user
system.
4. The EMLE pin can operate even if it is not connected to the E1 or E20 emulator. When the pin is
not connected to the E1 or E20 emulator, a special circuit for the pin must be configured on the
user system.
If the MCU does not have an EMLE pin, it is not necessary to connect it to the emulator
connector. In this case, only FINE Interface Connection is available.
5. The MD0 and MD1 pin can operate even if it is not connected to the E1 or E20 emulator. When
the pin is not connected to the E1 or E20 emulator, a special circuit for the pin must be
configured on the user system.
You cannot debug a program in boot mode.
R20UT0399EJ0700 Rev.7.00
Feb 01, 2014
Page 15 of 50