English
Language : 

HYS72T64000HP-25F Datasheet, PDF (26/65 Pages) Qimonda AG – 240-Pin Registered DDR2 SDRAM Modules
Internet Data Sheet
HYS72T[64/128/256]xxxHP–[25F/2.5/3/3S/3.7]–B
240-Pin Registered DDR2 SDRAM
Parameter
Symbol
DDR2–533
Min.
Max.
Unit
Note1)2)3)4)5)
6)7)
Average periodic refresh Interval
tREFI
—
Auto-Refresh to Active/Auto-Refresh
tRFC
105
command period
3.9
µs
16)18)
—
ns
17)
Precharge-All (4 banks) command period
Precharge-All (8 banks) command period
Read preamble
Read postamble
Active bank A to Active bank B command
period
Active bank A to Active bank B command
period
tRP
tRP
tRPRE
tRPST
tRRD
tRRD
tRP + 1tCK
15 + 1tCK
0.9
0.40
7.5
10
—
—
1.1
0.60
—
—
ns
—
ns
—
tCK
14)
tCK
14)
ns
14)18)
ns
16)22)
Internal Read to Precharge command delay
Write preamble
Write postamble
Write recovery time for write without Auto-
Precharge
Internal Write to Read command delay
Exit power down to any valid command
(other than NOP or Deselect)
Exit active power-down mode to Read
command (slow exit, lower power)
tRTP
tWPRE
tWPST
tWR
tWTR
tXARD
tXARDS
7.5
0.25
0.40
15
7.5
2
6 – AL
—
—
0.60
—
—
—
—
ns
—
tCK
—
tCK
19)
ns
—
ns
20)
tCK
21)
tCK
21)
Exit precharge power-down to any valid
tXP
2
command (other than NOP or Deselect)
—
tCK
—
Exit Self-Refresh to non-Read command
Exit Self-Refresh to Read command
Write recovery time for write with Auto-
Precharge
tXSNR
tXSRD
WR
tRFC +10
—
200
—
tWR/tCK
—
ns
—
tCK
—
tCK
22)
1) For details and notes see the relevant Qimonda component data sheet
2) VDDQ = 1.8 V ± 0.1 V; VDD = 1.8 V ±0.1 V.
3) Timing that is not specified is illegal and after such an event, in order to guarantee proper operation, the DRAM must be powered down
and then restarted through the specified initialization sequence before normal operation can continue.
4) Timings are guaranteed with CK/CK differential Slew Rate of 2.0 V/ns. For DQS signals timings are guaranteed with a differential Slew
Rate of 2.0 V/ns in differential strobe mode and a Slew Rate of 1 V/ns in single ended mode.
5) The CK / CK input reference level (for timing reference to CK / CK) is the point at which CK and CK cross. The DQS / DQS, RDQS / RDQS,
input reference level is the crosspoint when in differential strobe mode.
6) Inputs are not recognized as valid until VREF stabilizes. During the period before VREF stabilizes, CKE = 0.2 x VDDQ is recognized as low.
7) The output timing reference voltage level is VTT.
8) For each of the terms, if not already an integer, round to the next highest integer. tCK refers to the application clock period. WR refers to
the WR parameter stored in the MR.
9) The clock frequency is allowed to change during self-refresh mode or precharge power-down mode.
10) For timing definition, refer to the Component data sheet.
11) Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers as well as output Slew Rate
mis-match between DQS / DQS and associated DQ in any given cycle.
12) MIN (tCL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device (i.e. this value can
be greater than the minimum specification limits for tCL and tCH).
Rev. 1.1, 2007-03
26
03292006-EO3M-LEK7