English
Language : 

WC701 Datasheet, PDF (17/28 Pages) Pulse A Technitrol Company – RF Chip Inductors
wire-wound rf chip
inductors - 0805ft series
Wirewound ceramic core construction
High Q values and resonant frequency
Industry standard 0805 (2012) surface
mount land pattern
See page 3 for Competition Cross Reference
Part Number
PE-0805FT102KTT
PE-0805FT152KTT
PE-0805FT222KTT
PE-0805FT332KTT
PE-0805FT472KTT
PE-0805FT682KTT
PE-0805FT103KTT
PE-0805FT153KTT
PE-0805FT223KTT
PE-0805FT333KTT
PE-0805FT473KTT
PE-0805FT683KTT
Inductance 1
(nH)
1.0 @ 7.96MHz
1.5 @ 7.96MHz
2.2 @ 7.96MHz
3.3 @ 7.96MHz
4.7 @ 7.96MHz
6.8 @ 7.96MHz
10 @ 2.52MHz
15 @ 2.52MHz
22 @ 2.52MHz
33 @ 2.52MHz
47 @ 2.52MHz
68 @ 2.52MHz
Standard
Tolerance
±5% (J)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
±10% (K)
Electrical Specifications @ 25°C
Optional
Q2
Tolerance
(MIN)
15 @ 7.96MHz
±5% (J)
15 @ 7.96MHz
±5% (J)
15 @ 7.96MHz
±5% (J)
15 @ 7.96MHz
±5% (J)
15 @ 7.96MHz
±5% (J)
15 @ 7.96MHz
±5% (J)
10 @ 2.52MHz
±5% (J)
10 @ 2.52MHz
±5% (J)
10 @ 2.52MHz
±5% (J)
10 @ 2.52MHz
±5% (J)
10 @ 2.52MHz
±5% (J)
8 @ 2.52MHz
SRF 3
(MHz MIN)
63
60
58
50
43
36
30
23
20
17
14
11
RDC 4
(Ω MAX)
1.20
1.45
1.80
2.30
2.80
3.40
4.70
6.50
8.00
10.70
13.80
17.50
IDC 5
(mA MAX)
245
225
200
175
140
115
98
80
68
60
55
49
Notes:
1. Inductance measured using a HP4286A RF Impedance Analyzer. (Please note that
inductance information is not stamped on part, because of the extremely small size).
2. Q measured using a HP4291A RF Impedance Analyzer with a HP16193A Test Fixture.
3. SRF measured using a HP8753C Network Analyzer.
4. RDC measured using a Valhalla Scientific model 4100 ATC Digital Ohmeter.
5. Based on a 15�C maximum temperature rise.
Pulse Jack
16
www.pulseelectronics.com
WC701.O (01/15)
Electronics