English
Language : 

YRM2.DIODE Datasheet, PDF (7/19 Pages) PULS GmbH – DUAL REDUNDANCY MODULE
Y-Series
YRM2.DIODE
DC24-48V, 20A, DUAL REDUNDANCY MODULE
7. TERMINALS AND WIRING
Type
Solid wire
Stranded wire
American Wire Gauge
Max. wire diameter
Wire stripping length
Screwdriver
Recommended tightening torque
Input and output terminals
Screw terminals
IP20 Finger safe construction.
Suitable for field installation.
0.5-6mm2
0.5-4mm2
20-10 AWG
2.8mm (including ferrule)
7mm / 0.28inch
3.5mm slotted or Pozidrive No 2
0.8Nm / 7lb.in
Alarm-signal terminals
Screw terminals, pluggable
IP20 Finger safe construction.
Suitable for field installation.
0.2-1.5mm2
0.2-1.5mm2
22-14 AWG
6mm / 0.25inch
3mm slotted
0.4Nm / 3.5lb.in
Instructions:
a) The external circuitry of all terminals (including signalling contacts) must meet the safety requirements stipulated by
IEC/EN/UL 60950-1: SELV.
b) Use appropriate copper cables that are designed for minimum operating temperatures of:
60°C for ambient up to 45°C and
75°C for ambient up to 60°C minimum.
c) Follow national installation codes and installation regulations!
d) Ensure that all strands of a stranded wire enter the terminal connection!
e) Screws of unused terminal compartments should be securely tightened.
f) Ferrules are allowed.
g) Do not connect or disconnect the wires from the terminals below -25°C (-13°F).
Apr. 2014 / Rev. 1.4 DS-YRM2.DIODE-EN
All parameters are specified at 24V, 20A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted
www.pulspower.com Phone +49 89 9278 0 Germany
7/19