English
Language : 

YRM2.DIODE Datasheet, PDF (4/19 Pages) PULS GmbH – DUAL REDUNDANCY MODULE
Y-Series
YRM2.DIODE
DC24-48V, 20A, DUAL REDUNDANCY MODULE
3. INPUT AND OUTPUT CHARACTERISTICS
Number of inputs
-
2
Number of outputs
-
1
Input voltage
nom. DC 24-48V
±25%
The input circuitry must meet the SELV requirements
stipulated by IEC/EN/UL 60950-1.
Input voltage range
-
18-60Vdc
Voltage drop, input to output typ. 0.78V
at 2x5A, see Fig. 3-1
typ. 0.85V
at 1x10A, see Fig. 3-2
typ. 0.85V
at 2x10A, see Fig. 3-1
Input current
nom. 2x 0-10A
continuous
nom. 1x 0-20A
continuous, see note 1
nom. 2x 10-16A
for up to 5 seconds
Peak input current
max. 150A
for maximal 10ms per input
Output current
nom. 20A
continuous
nom. 20-32A
for up to 5 seconds
max. 25A
at continuous overload or short circuit, see note 2
Reverse current
max. 2mA
per input, -40°C to +60°C
Reverse voltage
max. 200Vdc
voltage applied to the output, continuously allowed
Note 1:
Note 2:
Each input can be loaded up to 20A. At currents above 10A, the other input should not be loaded. It is preferable to parallel the two
inputs in order to minimize the power loss in such cases.
Ensure that the continuous output current does not exceed 25A. Check the short-circuit current of the power sources and if the
power source can deliver more than 25A together, use an appropriate fuse on the output.
Fig. 3-1 Input to output voltage drop when both inputs draw current
(typical 1+1 redundant case, when the output voltages of the two units are equal or set into “parallel use” mode)
Voltage Drop, typ.
1000mV
800mV
600mV
400mV
200mV
0mV
Output: 0
Input: 0
A
B
A... 25°C
B... 60°C
Input, Output Current
5A 10A 15A 20A
2x2.5A 2x5A 2x7.5A 2x10A
QS/QT10
24V,10A
+
-
I1
A
V U1
YR2 / YRM2
Input 1
QS/QT10
24V,10A
+
-
I2
A
V U2
Input 2
I1 = I2
U1 = U2
Output
Output
IOUT
A
UOUT V
Variable
Load,
0-20A
Voltage Drop = U1 - UOUT
Fig. 3-2 Input to output voltage drop when only one input draws current
Voltage Drop, typ.
1000mV
800mV
A
600mV
400mV
200mV
0mV
0
5A
B
A... 25°C
B... 60°C
Output Current
10A 15A 20A
QS/QT20
24V,20A
+
-
I1
A
V U1
YR2 / YRM2
Input 1
Not used or
power supply
with lower
voltage
Input 2
Output
Output
IOUT
A
UOUT V
Variable
Load,
0-20A
Voltage Drop = U1 - UOUT
Apr. 2014 / Rev. 1.4 DS-YRM2.DIODE-EN
All parameters are specified at 24V, 20A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted
www.pulspower.com Phone +49 89 9278 0 Germany
4/19