EPR-85 Datasheet, PDF (27/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for EP 85 - 2 W Charger using LinkSwitch-LP
04-Oct-2005
EP-85 6 V, 330 mA Low Cost Charger
12 AC Line Surge
Input line 1.2/50 µs differential surge testing (2 Ω generator output impedance) was
completed on a single test unit to IEC61000-4-5. Input voltage was set at 230 VAC /
60 Hz. Output was loaded at full load with a 17 Ω resistor and operation was verified
during and following each surge event. Neither failures nor output glitches were seen.
Surge Testing Results
Surge
Input
Level (V) Voltage
(VAC)
+250
230
-250
230
+500
230
-500
230
+750
230
-750
230
+1000
230
-1000
230
Injection
Location
LN
LN
LN
LN
LN
LN
LN
LN
Phase
Injection (°)
90
90
90
90
90
90
90
90
Test Result
(Pass/Fail)
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Unit passes under all test conditions.