English
Language : 

EPR-85 Datasheet, PDF (13/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for EP 85 - 2 W Charger using LinkSwitch-LP
04-Oct-2005
EP-85 6 V, 330 mA Low Cost Charger
2 mm margin tape 1/4T to
set winding start position.
Start winding here from
edge of margin tape.
Plastic tape
Position three wires to
line up with outside edge
of margin tape and stick
wires down with plastic
tape.
No empty space among
the wires.
Figure 7 – Winding Method of Shield Winding.
Page 13 of 32
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com