ZY7010L Datasheet, PDF (4/34 Pages) Power-One – 10A DC-DC Intelligent POL 3V to 13.2V Input 0.5V to 5.5V Output
ZY7010L 10A DC-DC Intelligent POL Data Sheet
3V to 13.2V Input • 0.5V to 5.5V Output
Figure 1. Output Voltage as a Function of Input Voltage and Output Current
4.3 Protection Specifications
Parameter
Type
Threshold
Threshold Accuracy
Type
Threshold
Threshold Accuracy
Delay
Conditions/Description
Min
Nom
Max
Units
Output Overcurrent Protection
Default
Programmable
Default
Programmable in 11 steps
Non-Latching, 130ms period
Latching/Non-Latching
150
%IOUT
50
150
%IOUT
-25
25
%IOCP.SET
Output Overvoltage Protection
Default
Programmable
Default
Programmable in 10% steps
Measured at VO.SET=2.5V
From instant when threshold is exceeded until
the turn-off command is generated
Non-Latching, 130ms period
Latching/Non-Latching
1101
130
130
%VO.SET
%VO.SET
-2
2
%VOVP.SET
6
µs
ZD-00422 REV. 2.2
www.power-one.com
Page 4 of 34