ZY7010L Datasheet, PDF (17/34 Pages) Power-One – 10A DC-DC Intelligent POL 3V to 13.2V Input 0.5V to 5.5V Output
ZY7010L 10A DC-DC Intelligent POL Data Sheet
3V to 13.2V Input • 0.5V to 5.5V Output
8. Programmable Features
Performance parameters of ZY7010L POL
converters can be programmed via the industry
standard I2C communication bus without replacing
any components or rewiring PCB traces. Each
parameter has a default value stored in the volatile
memory registers detailed in Table 1. The setup
registers 00h through 14h are programmed at the
system power-up. When the user programs new
performance parameters, the values in the registers
are overwritten. Upon removal of the input voltage,
the default values are restored.
Table 1. ZY7010L Memory Registers
Register
Content
Address
PC1
Protection Configuration 1
00h
PC2
Protection Configuration 2
01h
PC3
Protection Configuration 3
02h
DON
Turn-On Delay
05h
DOF
Turn-Off Delay
06h
TC
Tracking Configuration
03h
INT
Interleave Configuration and
04h
Frequency Selection
RUN
RUN Register
15h
ST
Status Register
16h
VOS
Output Voltage Setpoint
07h
CLS
Current Limit Setpoint
08h
DCL
Duty Cycle Limit
09h
B1
Dig Controller Denominator z-1
0Ah
Coefficient
B2
Dig Controller Denominator z-2
0Bh
Coefficient
B3
Dig Controller Denominator z-3
0Ch
Coefficient
C0L
Dig Controller Numerator z0
0Dh
Coefficient, Low Byte
C0H
Dig Controller Numerator z0
0Eh
Coefficient, High Byte
C1L
Dig Controller Numerator z-1
0Fh
Coefficient, Low Byte
C1H
Dig Controller Numerator z-1
10h
Coefficient, High Byte
C2L
Dig Controller Numerator z-2
11h
Coefficient, Low Byte
C2H
Dig Controller Numerator z-2
12h
Coefficient, High Byte
C3L
Dig Controller Numerator z-3
13h
Coefficient, High Byte
C3H
Dig Controller Numerator z-3
14h
Coefficient, Low Byte
VOM
Output Voltage Monitoring
17h
IOM
Output Current Monitoring
18h
TMP
Temperature Monitoring
19h
ZY7010L converters can be programmed using the
Graphical User Interface or directly via the I2C bus by
using high and low level commands as described in
the ‘”DPM Programming Manual”.
ZY7010L parameters can be reprogrammed at any
time during the system operation and service except
for the digital filter coefficients, the switching
frequency and the duty cycle limit, that can only be
changed when the POL is turned off.
8.1 Output Voltage
The output voltage can be programmed in the GUI
Output Configuration window shown in the Figure 27
or directly via the I2C bus by writing into the VOS
register shown in Figure 28.
Figure 27. Output Configuration Window
R/W-0
VOS7
Bit 7
R/W-0
VOS6
R/W-0
VOS5
R/W-0
VOS4
R/W-0
VOS3
R/W-0
VOS2
R/W-0
VOS1
R/W-0
VOS0
Bit 0
Bit 7:0 VOS[7:0], Output voltage setting
00h: corresponds to 0.5000V
01h: corresponds to 0.5125V
…
77h: corresponds to 1.9875V
78h: corresponds to 2.0000V
79h: corresponds to 2.025V
…
F9h: corresponds to 5.225V
FAh: corresponds to 5.250V
FBh: corresponds to 5.300V
…
FFh: corresponds to 5.500V
R = Readable bit
W = Writable bit
U = Unimplemented bit,
read as ‘0’
- n = Value at POR reset
Figure 28. Output Voltage Setpoint Register VOS