4. Electrical Specifications
Specifications apply at the input voltage from 3V to 13.2V, output load from 0 to 10A, ambient temperature from -
40°C to 85°C, 100µF output capacitance, and default performance parameters settings unless otherwise noted.
4.1 Input Specifications
Parameter
Input voltage (VIN)
Conditions/Description
Min
At VIN<4.75V, VLDO pin needs to be
connected to an external voltage source
3
higher than 4.75V
Input Current (at no load)
VIN≥4.75V, VLDO pin connected to VIN
Undervoltage Lockout (VLDO
connected to VIN)
Ramping Up
Ramping Down
Undervoltage Lockout (VLDO
connected to VAUX=5V)
Ramping Up
Ramping Down
External Low Voltage Supply
Connect to VLDO pin when VIN<4.75V
4.75
VLDO Input Current
Current drawn from the external low
voltage supply at VLDO=5V
Nom
50
4.2
3.75
3.0
2.5
50
Max
Units
13.2
VDC
mADC
VDC
VDC
VDC
VDC
13.2
VDC
mADC
4.2 Output Specifications
Parameter
Output Voltage Range (VOUT)
Output Voltage Setpoint Accuracy
Output Current (IOUT)
Line Regulation
Load Regulation
Dynamic Regulation
Peak Deviation
Settling Time
Output Voltage Peak-to-Peak
Ripple and Noise
BW=20MHz
Full Load
Temperature Coefficient
Switching Frequency
Duty Cycle Limit
Conditions/Description
Programmable1
Default (no programming)
VIN=12V, IOUT=0.5*IOUT MAX,
FSW=500kHz, room temperature
VIN MIN to VIN MAX
VIN MIN to VIN MAX
0 to IOUT MAX
Slew rate 2.5A/µs, 50 -100% load step
COUT=220µF, FSW=1MHz
to 10% of peak deviation
VIN=5.0V, VOUT=0.5V, FSW=500kHz
VIN=5.0V, VOUT=2.5V, FSW=500kHz
VIN=12V, VOUT=0.5V, FSW=500kHz
VIN=12V, VOUT=2.5V, FSW=500kHz
VIN=12V, VOUT=5.0V, FSW=500kHz
VIN=12V, IOUT=0.5*IOUT MAX
Default
Programmable, 250kHz steps
Default
Programmable, 1.56% steps
Min
Nom
Max
0.5
5.5
0.5
(See Ordering Information)
-102
10
±0.4
±0.3
50
200
10
15
15
25
45
20
500
500
1,000
90.5
0
95
Units
VDC
VDC
ADC
%VOUT
%VOUT
mV
µs
mV
mV
mV
mV
mV
ppm/°C
kHz
kHz
%
%
1 ZY7010L is a step-down converter, thus the output voltage is always lower than the input voltage as show in Figure 1.
2 At the negative output current (bus terminator mode) efficiency of the ZY7010L degrades resulting in increased internal power dissipation.
Therefore maximum allowable negative current under specific conditions is 20% lower than the current determined from the derating curves
shown in paragraph 5.5.
ZD-00422 REV. 2.2
www.power-one.com
Page 3 of 34