PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 425H, 465H, 4A5H: RTTB, TU #2 in TUG2 #1 to TUG2 #7, TIU
Interrupt
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R
R
R
R
R
R
Function
Unused
TIU7I
TIU6I
TIU5I
TIU4I
TIU3I
TIU2I
TIU1I
Default
X
0
0
0
0
0
0
0
This register is used to identify and acknowledge trail trace identifier unstable
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
TIU1I-TIU7I:
The TIU1I to TIU7I bits identify the source of trail trace identifier unstable
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated TIUxI bit is unused and will return a logic 0 when
read. When operational, the TIU1I to TIU7I bits report and acknowledge TIU
interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated upon change of identifier unstable state. An TIUxI bit is set high
when a trail trace identifier unstable event on the corresponding tributary (TU
#2 in TUG2 #x ) occurs and are cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. TIUxI remains
valid when interrupts are not enabled (TIUE set low) and may be polled to
detect trail trace identifier unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 253