English
Language : 

PM5362-1 Datasheet, PDF (268/354 Pages) –
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6 SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 421H, 461H, 4A1H: RTTB, TU #2 in TUG2 #1 to TUG2 #7, TIM
Interrupt
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R
R
R
R
R
R
Function
Unused
TIM7I
TIM6I
TIM5I
TIM4I
TIM3I
TIM2I
TIM1I
Default
X
0
0
0
0
0
0
0
This register is used to identify and acknowledge trail trace identifier mismatch
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
TIM1I-TIM7I:
The TIM1I to TIM7I bits identify the source of trail trace identifier mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated TIMxI bit is unused and will return a logic 0 when
read. When operational, the TIM1I to TIM7I bits report and acknowledge TIM
interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated upon change of identifier mismatch state. An TIMxI bit is set high
when a trail trace identifier mismatch event on the corresponding tributary
(TU #2 in TUG2 #x) occurs and are cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. TIMxI
remains valid when interrupts are not enabled (TIME set low) and may be
polled to detect trail trace identifier mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 248