English
Language : 

SA606_15 Datasheet, PDF (9/33 Pages) NXP Semiconductors – Low-voltage high performance mixer FM IF system
NXP Semiconductors
SA606
Low-voltage high performance mixer FM IF system
Table 7. Dynamic characteristics …continued
Tamb = 25 C; VCC = 3 V; unless specified otherwise. RF frequency = 45 MHz + 14.5 dBV RF input step-up.
IF frequency = 455 kHz; R17 = 2.4 k and R18 = 3.3 k. RF level = 45 dBm; FM modulation = 1 kHz with 8 kHz peak
deviation. Audio output with de-emphasis filter and C-message weighted filter. Test circuit Figure 19. The parameters listed
below are tested using automatic test equipment to assure consistent electrical characteristics. The limits do not represent
the ultimate performance limits of the device. Use of an optimized RF layout will improve many of the listed parameters.
Symbol Parameter
Conditions
Min Typ Max Unit
Zo(lim)
limiter output impedance
LIMITER_OUT pin
-
0.3 -
k
Vo(RMS) RMS output voltage
LIMITER_OUT pin
-
130 -
mV
RF/IF section (internal LO)
Vo(aud)RMS RMS audio output voltage
VCC = 3 V; RF level = 27 dBm
-
120 -
mV
Vo(RSSI) RSSI output voltage
system; VCC = 3 V;
RF level = 27 dBm
-
2.2 -
V
SINAD signal-to-noise-and-distortion ratio system; RF level = 117 dBm
-
12
-
dB
12. Performance curves
SA606
Product data sheet
6
ICC
(mA)
5
4
3
VCC = 7.0 V
5.0 V
3.0 V
2.7 V
002aaf410
2
−55
−35
−15
5
25
45
65
Fig 4. Supply current versus ambient temperature
−8.0
IP3i
(dBm)
−9.0
−10.0
VCC = 2.7 V
3.0 V
7.0 V
85
105
125
Tamb (°C)
002aaf411
−11.0
−12.0
−13.0
−14.0
−40
−20
0
20
40
60
80 90
Tamb (°C)
Fig 5. Third order intercept point versus ambient temperature and supply voltage
All information provided in this document is subject to legal disclaimers.
Rev. 6 — 8 November 2013
© NXP B.V. 2013. All rights reserved.
9 of 33