 Features (continued)
 Timer counter (continued)
Timer 10 (8-bit timer for general use)
Interval timer, Timer pulse output, Event count, Cascade connection (Connected to Timer 9)
Count clock source: IOCLK, IOCLK/8, IOCLK/32, IOCLK/128, TM10IO pin input
Timer 8 underflow, Timer 9 underflow
Timer 11 (8-bit timer for general use)
Interval timer, Timer pulse output, Event count, Cascade connection (Connected to Timer 10)
Count clock source: IOCLK, IOCLK/8, IOCLK/32, IOCLK/128, TM11IO pin input
Timer 8 underflow, Timer 9 underflow, Timer 10 underflow
Timer 16 (16-bit timer for general use)
Interval timer, Event count, Up/down count, Timer output, PWM output, Input capture, one-shot output, External trigger start
Count clock source: IOCLK, IOCLK/8, IOCLK/64, Timer 7 underflow, TM16BIO pin input
Timer 17 (16-bit timer for general use)
Interval timer, Event count, Up/down count, Timer output, PWM output, Input capture, one-shot output, External trigger start
Count clock source: IOCLK, IOCLK/8, IOCLK/64, Timer 11 underflow, TM17BIO pin input
Timer 18 (16-bit timer for general use)
Interval timer, Event count, Up/down count, Timer output, PWM output (output to 6 ports all at once is possible),
Input capture, one-shot output, External trigger start
Count clock source: IOCLK, IOCLK/8, Timer 6 underflow, Timer 7 underflow, TM18BIO pin input
Timer 19 (16-bit timer for general use)
Interval timer, Event count, Up/down count, Timer output, PWM output, Input capture, one-shot output, External trigger start
Count clock source: IOCLK, IOCLK/8, Timer 10 underflow, Timer 11 underflow, TM19BIO pin input
Timer 20 (16-bit timer for general use)
Interval timer, Event count *, Up/down count, Timer output *, PWM output *, Input capture *, one-shot output *,
External trigger start *, Start by PWM0 overflow/underflow interrupt, A/D conversion start trigger generation
Count clock source: MCLK, MCLK/8, IOCLK, IOCLK/8, Timer 6 underflow,
Timer 7 underflow, TM20BIO pin input *
*: only MN103SFK0K
Timer 21 (16-bit timer for general use)
Interval timer, Event count *, Up/down count, Timer output *, PWM output *, Input capture *, one-shot output *,
External trigger start *, PWM1 overflow/underflow interrupt, A/D conversion start trigger generation
Count clock source: MCLK, MCLK/8, IOCLK, IOCLK/8, Timer 10 underflow,
Timer 11 underflow, TM21BIO pin input *
*: only MN103SFK0K
Timer 23 (16-bit timer for general use)
Interval timer, Event count, Up/down count, Timer output, PWM output (output to 6 ports all at once is possible),
Input capture, one-shot output, External trigger start
Count clock source: IOCLK, IOCLK/8, Timer 10 underflow, Timer 11 underflow, TM23BIO pin input
 Watchdog Timer
Detection time 6.55 ms to 1677.72 ms (oscillation frequency 10 MHz)
Generates non-maskable interrupt at detection
Generates hard-reset at second consective overflow
Ver. AEM