ERZ-E14A471 Datasheet, PDF (2/18 Pages) Panasonic Semiconductor – “ZNR” Transient/Surge Absorbers (Type D) | |||
|
◁ |
âZNRâ Transient/Surge Absorbers (Type D)
â Reference Guide to Standard Products
Part No.
ERZE05A201
Applicable
Standards
Type
Name
Approvals
E201 ËËË
Varistor
Voltage
at 1 mA
Maximum
Allowable
Voltage
Clamping
Voltage
at 8/20μs
Maximum
Peak Current
at 8/20μs(A)
Recommended Applications
(V) ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times
340 10 1200 600
ERZE07A201 E7201 ËËË
340 25 2500 1250
ERZE08A201 E8201
ERZE10A201 E10201
ËËË
ËËË
200
(185 to 225)
130
170
340
340
25 3500 2500
50 4500 3000
ERZE11A201 E11201 ËËËËËË
340 50 6000 5000
ERZE14A201 E14201 ËËËËËË
ERZE05A221
E221 ËËË
340 100 10000 7000 AC 100 V LineâLine
360 10 1200 600 Applications
ERZE07A221 E7221 ËËË
360 25 2500 1250
ERZE08A221 E8221
ERZE10A221 E10221
ËËË
ËËË
220
(198 to 242)
140
180
360
360
25 3500 2500
50 4500 3500
ERZE11A221 E11221 ËËËËËË
360 50 6000 5000
ERZE14A221 E14221 ËËËËËË
360 100 10000 7000
ERZE05A241
E241 ËËË
395 10 1200 600
ERZE07A241 E7241 ËËË
395 25 2500 1250
ERZE08A241 E8241
ERZE10A241 E10241
ËËË
ËËË
240
(216 to 264)
150
200
395
395
25 3500 2500
50 4500 3000
ERZE11A241 E11241 ËËËËËË
395 50 6000 5000
ERZE14A241 E14241 ËËËËËË
ERZE05A271
E271 ËËË
395 100 10000 7000 AC 100 V to 120 V, LineâLine
455 10 1200 600 Applications
ERZE07A271 E7271 ËËË
455 25 2500 1250
ERZE08A271 E8271
ERZE10A271 E10271
ËËË
ËËË
270
(247 to 303)
175
225
455
455
25 3500 2500
50 4500 3000
ERZE11A271 E11271 ËËËËËË
455 50 6000 5000
ERZE14A271 E14271 ËËËËËË
455 100 10000 7000
ERZE05A331
E331 ËËË
545 10 1200 600
ERZE07A331 E7331 ËËË
545 25 2500 1250
ERZE08A331 E8331
ERZE10A331 E10331
ËËË
ËËË
330
(297 to 363)
210
270
545
545
25 3500 2500
50 4500 3000
ERZE11A331 E11331 ËËËËËË
545 50 6000 4500
ERZE14A331 E14331 ËËËËËË
545 100 10000 6500
ERZE05A361
E361 ËËË
595 10 1200 600
ERZE07A361 E7361 ËËË
595
25
2500
1250
AC 100 V to 120 V, LineâLine
Applications
ERZE08A361 E8361
ERZE10A361 E10361
ËËË
ËËË
360
(324 to 396)
230
300
595
595
25 3500 2500
50 4500 3000 Telephone Line Applications,
(For DC 250 V Insulation
ERZE11A361 E11361 ËËËËËË
595 50 6000 4500 Resistance Test)
ERZE14A361 E14361 ËËËËËË
595 100 10000 6500
ERZE05A391
E391 ËËË
650 10 1200 600
ERZE07A391 E7391 ËËË
650 25 2500 1250
ERZE08A391 E8391
ERZE10A391 E10391
ËËË
ËËË
390
(351 to 429)
250
320
650
650
25 3500 2500
50 4500 3000
ERZE11A391 E11391 ËËËËËË
650 50 6000 4500
ERZE14A391 E14391 ËËËËËË
650 100 10000 6500
ERZE05A431
E431 ËËË
710 10 1200 600
ERZE07A431 E7431 ËËË
710 25 2500 1250
ERZE08A431 E8431
ERZE10A431 E10431
ËËË
ËËË
430
(387 to 473)
275
350
710
710
25 3500 2500 AC 100 V to 220 V, LineâLine
and
50 4500 3000 LineâGround Applications
ERZE11A431 E11431 ËËËËËË
710 50 6000 4500
ERZE14A431 E14431 ËËËËËË
710 100 10000 6500
Ë : UL1449 (VZCA2/UL, VZCA8/C-UL), Ë : UL1449 Type3 (or Code-Connected and Direct plug-in),
Ë : UL1449 Type2 (or Permanently Connected), Ë : VDE (IEC61051-1, -2, -2-2), Ë : VDE (IEC60950-1 Annex.Q)
Ë : CQC (GB/T10193, GB/T10194), Ë : CQC (GB4943.1, GB8898)
ËApproval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and speciï¬cations are each subject to change without notice. Ask factory for the current technical speciï¬cations before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
07 Dec. 2013
|
▷ |