CAT705, CAT706, CAT813
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Typical values at TA = 25°C and VCC = 5 V for CAT705, CAT706 and
CAT813 versions. VCC = 3.3 V for the CAT706 T/S versions; VCC = 3.0 V for the CAT706 R version.) (Note 1)
Parameter
Symbol
Test Conditions
Min
Typ
Max
Units
WATCHDOG INPUT
WDO Output Voltage
VW_OH VRST (max) < VCC < 3.6 V;
0.8 x VCC
V
ISOURCE = −500 mA
4.5 V < VCC < 5.5 V,
ISOURCE = −800 mA
VCC – 1.5 VCC – 0.25
VW_OL VRST (max) < VCC < 3.6 V,
0.3
ISINK = +500 mA
4.5 V < VCC < 5.5 V,
ISINK = 1.2 mA
0.1
0.4
WDO to WDI setup time (Note 5)
MANUAL RESET INPUT
tWDSU
250
ns
MR Input Voltage
MR Pull−up Current
VIL
VIH
MR = 0 V
0.3 x VCC
V
0.7 x VCC
40
70
140
mA
MR Pulse Width
MR Pull−up Resistance
MR low to Reset Delay (Note 4)
POWER−FAIL INPUT
tPB
RMR
tPDLY
1
ms
40
60
80
kW
5
ms
PFI Input Threshold
PFI Input Current
VCC = 5 V
1.2
1.25
1.3
V
−25
0.01
25
nA
PFO Output Voltage
VP_OH VRST(max) < VCC < 3.6 V,
0.8 x VCC
V
ISOURCE = −500 mA
4.5 V < VCC < 5.5 V,
VCC −
0.4
ISOURCE = −800 mA
1.5
VP_OL VRST (max) < VCC < 3.6 V,
0.3
ISINK = +1.2 mA
4.5 V < VCC < 5.5 V, ISINK = 3.2 mA
0.4
1. Limits are guaranteed by design and not production tested.
2. The RESET short−circuit current is the maximum pull−up current when reset is driven low by a bidirectional output.
3. WDI is internally serviced within the watchdog period if WDI is left open.
4. RESET for CAT705 & CAT706 & RESET for CAT813.
5. Not 100% tested but guaranteed by design.
http://onsemi.com