CAT705, CAT706, CAT813
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Typical values at TA = 25°C and VCC = 5 V for CAT705, CAT706 and
CAT813 versions. VCC = 3.3 V for the CAT706 T/S versions; VCC = 3.0 V for the CAT706 R version.) (Note 1)
Parameter
Symbol
Test Conditions
Min
Typ
Max
Units
Supply Current
ICC
CAT705, CAT706, CAT813
CAT706 (R/S/T Versions)
6
17
mA
4
12
mA
Reset Threshold
VRST
CAT705 & CAT813 at
−40°C ≤ TA ≤ +85°C
4.50
4.65
4.75
V
Reset Threshold Tempco (Note 1)
CAT706 at −40°C ≤ TA ≤ +85°C
4.25
CAT706T at −40°C ≤ TA ≤ +85°C
3.00
CAT706S at −40°C ≤ TA ≤ +85°C
2.85
CAT706R at −40°C ≤ TA ≤ +85°C
2.55
4.40
3.08
2.93
2.63
40
4.50
V
3.15
V
3.00
V
2.70
V
ppm/°C
Reset Threshold Hysteresis
(Note 1)
CAT705 & CAT813
CAT706
10
mV
5
mV
VCC to Reset Delay (Note 2)
Reset Active Timeout Period
RESET Output High Voltage
tRD
VCC = VTH to (VTH – 100 mV)
20
tRP
140
200
VOH
CAT705 & CAT706, 4.5 V < VCC <
VCC −
5.5 V, ISOURCE = −800 mA
1.5 V
ms
400
ms
V
CAT705 & CAT706, VRST (max) <
VCC < 3.6 V, ISOURCE = −500 mA
0.8 x VCC
RESET Output Low Voltage
VOL
CAT705 & CAT706, 4.5 V < VCC <
5.5 V, ISINK = 3.2 mA
0.4
V
CAT705 & CAT706, VRST (max) <
0.3
VCC < 3.6 V, ISINK = 1.2 mA
CAT705 &CAT706, VCC = 1 V,
0.3
ISINK = 100 mA
RESET Output High Voltage
VOH
CAT813, VCC = VRST max,
VCC −
V
ISOURCE = −120 mA
1.5 V
CAT813, VCC = VRST max,
ISOURCE = −30 mA
0.8 x VCC
RESET Output Low Voltage
VOL
CAT813, VCC = VRST min,
ISINK = 3.2 mA
0.4
V
CAT813, VCC = 1.2 V,
0.3
ISINK = 100 mA
WATCHDOG INPUT
Watchdog Timeout Period
WDI Pulse Width
WDI Input Voltage (Note 3)
WDI Input Current (Note 3)
tWD
tWP
VIL = 0.4 V, VIH = 0.8 x VCC
VIL
VIH
WDI = VCC, Time Average
WDI = 0 V, Time Average
1.00
1.6
2.25
s
50
ns
0.3 x VCC
V
0.7 x VCC
50
150
mA
−150
−50
1. Limits are guaranteed by design and not production tested.
2. The RESET short−circuit current is the maximum pull−up current when reset is driven low by a bidirectional output.
3. WDI is internally serviced within the watchdog period if WDI is left open.
4. RESET for CAT705 & CAT706 & RESET for CAT813.
5. Not 100% tested but guaranteed by design.
http://onsemi.com
4