NOIL2SM1300A Datasheet, PDF (31/44 Pages) ON Semiconductor – LUPA1300-2: High Speed CMOS Image Sensor | |||
|
◁ |
NOIL2SM1300A
The reset levels are configured through external (power)
pins. In master mode, the time stamps of the double and
triple slope resets are configured in a method similar to
configuring the exposure time. The time stamps are enabled
through the registers seqmode1[5] and seqmode1[6], and
their values are expressed in line or clock cycles in the
registers reg_tint_ds_timer and reg_tint_ts_timer.
Figure 30. Triple Slope Timing in Master Mode
In slave mode, the values of res_length, tint_timer,
tint_DS_timer, and tint_TS_timer in the configuration
registers are ignored. You have full control through the pins
int_time, int_time_ds, and int_time_ts. You must configure
the multiple slope parameters for the application and
interpret the pixel data accordingly.
Figure 31. Triple Slope Timing in Slave Mode
http://onsemi.com
31
|
▷ |