English
Language : 

CM1693-04DE Datasheet, PDF (3/8 Pages) ON Semiconductor – L-C LCD and Camera EMI Filter Array with ESD Protection
CM1693−04DE, CM1693−06DE, CM1693−08DE
SPECIFICATIONS
Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Storage Temperature Range
–65 to +150
°C
Current per Inductor
30
mA
DC Package Power Rating
500
mW
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Operating Temperature Range
Rating
–40 to +85
Units
°C
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note 1)
Symbol
Parameter
Conditions
Min Typ Max Units
L
Channel Inductance
26
nH
CTOTAL Total Channel Capacitance
At 2.5 VDC Reverse Bias, 17.6 22 26.4
pF
1 MHz, 30 mVAC
VDIODE
ILEAK
VSIG
VESD
Standoff Voltage
Diode Leakage Current (reverse bias)
Signal Clamp Voltage
Positive Clamp
Negative Clamp
In−system ESD Withstand Voltage
Contact Discharge per IEC 61000−4−2 Level 4
IDIODE = 10 mA
VDIODE = +3.3 V
ILOAD = 10 mA
ILOAD = –10 mA
(Notes 2, 3 and 4)
5.5
V
0.1
1.0
mA
V
5.6
6.8
9.0
–1.5 –0.8 −0.4
kV
±18
RDYN
Dynamic Resistance
Positive
Negative
W
2.3
0.9
fR
Roll−off Frequency at −6 dB Attenuation
ZSOURCE = 50 W, ZLOAD = 50 W
MHz
300
1. TA = 25°C unless otherwise specified.
2. ESD applied to input and output pins with respect to GND, one at a time.
3. Clamping voltage is measured at the opposite side of the EMI filter to the ESD pin (i.e. if ESD is applied to pin A1 then clamping voltage is
measured at pin C1). Unused pins are left open.
4. These parameters are guaranteed by design and characterization.
http://onsemi.com
3