English
Language : 

AMIS30532C5321G Datasheet, PDF (27/29 Pages) ON Semiconductor – Micro-Stepping Motor Driver
AMIS−30532
Table 17. SPI STATUS FLAGS OVERVIEW
Mnemonic
Flag
Length
(bit) Related SPI Register
Comment
Reset
State
CPFail Charge pump failure
1
Status Register 0 ‘0’ = no failure
‘0’
‘1’ = failure: indicates that the charge pump does
not reach the required voltage level. Note 1
MSP[6:0] Micro−step position
7
Status Register 3 Translator micro step position
‘0000000’
OPENX OPEN Coil X
1
Status Register 0 ‘1’ = Open coil detected
‘0’
OPENY OPEN Coil Y
1
Status Register 0 ‘1’ = Open coil detected
‘0’
OVCXNB OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXN
terminal; Bottom
tran.
‘1’ = failure: indicates that over current is
detected at bottom transistor XN−terminal
OVCXNT OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXN
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor XN−terminal
transist.
OVCXPB OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXP
‘1’ = failure: indicates that over current is
terminal; Bottom
detected at bottom transistor XP−terminal
tran.
OVCXPT OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXP
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor XP−terminal
transist.
OVCYNB OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYN
‘1’ = failure: indicates that over current is
terminal; Bottom
detected at bottom transistor YN−terminal
tran.
OVCYNT OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYN
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor YN−terminal
transist.
OVCYPB OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYP
‘1’ = failure: indicates that over current is
terminal; Bottom
detected at bottom transistor YP−terminal
tran.
OVCYPT OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYP
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor YP−terminal
transist.
TSD
Thermal shutdown
1
Status Register 2
‘0’
TW
Thermal warning
1
Status Register 0
‘0’
WD
Watchdog event
1
Status Register 0 ‘1’ = watchdog reset after time−out
‘0’
NOTE: WD − This bit indicates that the watchdog timer has not been cleared properly. If the master reads that WD is set to “1” after reset,
it means that a watchdog reset occurred (warm boot) instead of POR (cold boot). WD bit will be cleared only when the master
writes “0” to WDEN bit.
Table 18. ORDERING INFORMATION
Part No.
Peak Current
Temperature
Range
Package
Shipping†
AMIS30532C5321RG
1600 mA
−40°C to 125°C
NQFP−32 (7 x 7 mm)
(Pb−Free)
Tape & Reel
AMIS30532C5321G
1600 mA
−40°C to 125°C
NQFP−32 (7 x 7 mm)
(Pb−Free)
Tube
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
27