H3DK Datasheet, PDF (9/30 Pages) Omron Electronics LLC – Solid-state Timers
H3DK-M/H3DK-S
■ Timing Charts
• There is no start input with the H3DK-S. Timer operation starts when the power is turned ON.
• There is no instantaneous output with the H3DK-@1.
A: ON Delay
t
Power (A1 and A2)
Start (B1 and A1)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NO
(21 and 24)
Power indicator
t−a
t
Basic Operation
Power
* **
Start input
Output
Timing
* For power ON-delay operation, connect start input
terminals B1 and A1. The Timer starts operating
as soon as the power turns ON.
** The start input is ignored while the Timer is in
operation.
B: Flicker OFF Start
Power (A1 and A2)
Start (B1 and A1)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NO
(21 and 24)
Power indicator
B2: Flicker ON start
t−a
t
t
t−a
t
t
t
Basic Operation
Power
*
Start input
Output
**
Timing
Timing Timing
Timing
* To start with the power supply, connect start input
terminals B1 and A1. The Timer starts operating
as soon as the power turns ON.
** The start input is ignored while the Timer is in
operation.
Power (A1 and A2)
Start (B1 and A1)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NO
(21 and 24)
Power indicator
C: Signal ON/ OFF Delay
t−a
t
t
t−a
t
t
t
Basic Operation
Power
*
Start input
Output
**
Timing
Timing Timing
Timing
* To start with the power supply, connect start input
terminals B1 and A1. The Timer starts operating
as soon as the power turns ON.
** The start input is ignored while the Timer is in
operation.
t
t
Power (A1 and A2)
Start (B1 and A1)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NO
(21 and 24)
Power indicator
t
t−a
t
t−a
Basic Operation
Power
*
Start input
Output
Timing
Timing
Timing
Timing
* The start input is valid while the Timer is in
operation.
Note 1.The reset time is 0.1 s min. Make sure the signal input time is 0.05 s or longer.
Note 2.“t” is the set time. “t−a” is a time that is less that the set time.