Specifications
Ratings/Characteristics
Amplifier Unit
Item
General-purpose
Multi-function
Four-channel
Waterproof Waterproof
red light green light
source
source
NPN/PNP output
Indicator
E3X-NT11 E3X-NT41 E3X-NT21 E3X-NT51
NPN
PNP
NPN
PNP
Orange LED: Lit during output operation
Green LED: Lit with stable light reception or no light
E3X-NM11
NPN
E3X-NM41
PNP
E3X-NV21
NPN
E3X-NVG21
NPN
Circuit protection
Ambient
temperature
Ambient humidity
Ambient
illumination
Insulation
resistance
Reverse polarity, output short-circuit, mutual interference prevention
Operating:–25°C to 55°C (with no icing)
Storage: –40°C to 70°C (with no icing)
Operating: 35% to 85% (with no condensation)
Sunlight: 10,000 ȏx max.; Incandescent lamp: 3,000 ȏx max.
20 MΩ min. (at 500 VDC)
Dielectric strength
Vibration
resistance
Shock resistance
Degree of
protection
Material
1,000 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude or 300 m/s2 (approx. 30G) for 2 hrs each in X, Y, and Z directions
500 m/s2 (approx. 50G) for 3 times each in X, Y, and Z directions
IEC60529 IP50 (with protective cover in place)
Case: PBT; Cover: Polycarbonate
IEC60529 IP66 (with
protective cover in place)
Case: Heat-resisting ABS;
Cover: Polycarbonate
Cord length
Connection
method
Weight (with 2-m
cord)
Prewired (2 m)
Vcc:
Brown
0 V:
Blue
Control output: Black
Remote teaching input: Pink (E3X-NT21/-NT51 only)
Approx. 100 g
Vcc:
Brown
0 V:
Blue
Control output 1: Black
Control output 2: White
Control output 3: Grey
Control output 4: Orange
Remote teaching input:
Pink
Approx. 200 g
Vcc:
Brown
0 V:
Blue
Control output : Black
Remote teaching input:
Pink
Approx. 100 g
Fiber Unit
Common
Ambient storage
temperature
Ambient storage humidity
Vibration resistance
Shock resistance
Heat-resistive fiber: –40°C to 110°C (with no icing)
Other fibers:
–40°C to 70°C (with no icing)
Operating: 35% to 95% (with no condensation)
10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions
500 m/s2 (approx. 50G) for 3 times each in X, Y, and Z directions