E3X-MDA11 Datasheet, PDF (6/14 Pages) Omron Electronics LLC – OMRONs Next-generation Platform for a Wide Range of Detection
E3X-DA-S/MDA
Advanced models
Type
External input models Twin output models ATC function models Analog output models
Item
Model E3X-DA@RM-S
E3X-DA@TW-S
E3X-DA@AT-S
E3X-DA@AN-S
Light source (wavelength) Red LED (635 nm)
Power supply voltage
12 to 24 VDC ”10%, ripple (p-p) 10% max.
Power consumption
1,080mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
2-channel models
E3X-MDA@
ON/OFF output
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Control
output
Analog output
---
Protection circuits
Reverse polarity for power supply connection, output short-circuit
Super-high-speed mode
Operate: 48 Ps,
reset: 50 Ps *1, *2, *3
Operate or reset:
80Ps *1
Response
time
High-speed mode
Operate or reset: 250 Ps
Standard mode Operate or reset: 1ms
Operate or reset:
130 Ps *1
High-resolution mode Operate or reset: 4ms
Sensitivity setting
Teaching or manual method
Power tuning Light emission power and reception gain, digital control method
Control output
Voltage output: 1 to
5 VDC
(Connection load 10
k: min.)
Temperature char-
acteristics
0.3%F.S./“C
Response speed/
repeat accuracy
Super-high-speed mode:
80 Ps/1.5%F.S.
High-speed mode:
250 Ps/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
Operate or reset:
80 Ps *1
---
Operate or reset:
130 Ps *1, *4
Operate or reset: 450 Ps
Differential de-
tection
Timer function
Switchable between single edge and double edge detection mode
Single edge: Can be set to 250 Ps, 500 Ps, 1 ms, 10 ms, or 100 ms.
---
Double edge: Can be set to 500 Ps, 1 ms, 2 ms, 20 ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-
ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power
control (APC)
High-speed control method for emission current
Zero-reset
Initial reset
Functions Mutual interfer-
ence prevention
Counter
I/O setting
Display
Negative values can be displayed. (Threshold value is shifted.)
Settings can be returned to defaults as required.
Possible for up to 10 Units *5
Switchable between
up counter and down
counter.
Set count:
0 to 9,999,999
External input set-
ting (Select from
teaching, power tun-
ing, zero reset, light
OFF, or counter re-
set.)
Operation indicator
(orange), Power
Tuning indicator (or-
ange)
---
Output setting
(Select from channel
2 output, area out-
put, or self-diagno-
sis.)
Output setting (Se-
lect from channel 2
output, area output,
self-diagnosis out-
put, or ATC error
output)
Operation indicator for channel 1 (orange),
Operation indicator for channel 2 (orange)
Analog output set-
ting (offset voltage
adjustable)
Operation indicator
(orange),
Power Tuning indi-
cator (orange)
Possible for up to 9
Units (18 channels) *6
Output setting
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Operation indicator for
channel 1 (orange),
Operation indicator for
channel 2 (orange)
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 Ps, reset: 55 Ps.
*3. When counter is enabled: 80 Ps for operate and reset respectively.
*4. When differential output is selected for the output setting, the second channel output is 200 Ps for operation and reset respectively.
*5. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*6. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
6