E3X-MDA11 Datasheet, PDF (2/14 Pages) Omron Electronics LLC – OMRONs Next-generation Platform for a Wide Range of Detection
E3X-DA-S/MDA
Models available for a wide variety of applications at manufacturing sites
Industry Leading Two Amplifiers Loaded in a Small Body . . . . 2-channel models
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
(compared to the value per channel of the former
model)
20mm
Liquid crystal board installation and alignment check
10mm
2-channel models
E3X-MDA
Simpler Digital Fiber Sensors . . . . Simple & Easy Single-function Models
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
Current value
UP/DOWN keys
Threshold value adjustment
Threshold value
Key lock switch
Operation mode
selection switch
TEACH key
Threshold value teaching
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
High-speed and High-resolution Analog Output Supports Wide Variety of Applications . . . .Advanced Analog
Output Models
Analog Control Output
High-speed and High Resolution
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
Detection modes can be switched in accordance with applications.
High-speed response of 80 Ps (super-high-speed mode) supports the
positioning controls that require high-speed control.
Sheet Displacement
ON/OFF
Analog
Area Output Function Area Judgment Is Possible . . . .Advanced, Twin-
output Models
Only one sensor is enough for area judgment for height or others that has re-
quired multiple sensors.
Setting two threshold values allows easy output inside and outside range.
Area Output
Incident
level
2000
1000
Output
ON
OFF
Threshold
value 1
Threshold
value 2
Time
Remote Input Function Sensors Controlled from Outside . . . .Advanced, External-
input Models
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Tablet length detection
Sticker detection
Equipped with an Industry's First ATC Function that Resolves Problems
at Manufacturing Sites . . . .Advanced ATC Models
OMRON’s unique algorism is equipped to
Fixed Threshold Value Method (Conventional Models) Corrected Threshold Value Method (ATC Models)
distinguish dust or dirt and the change of
2000
workpieces. Automatic correction of threshold
values by sensors in accordance with changes Incident level
prevents malfunctions and improves the operating (digital value)
1800
2000
Threshold value
set as an
Incident level
absolute value (digital value)
−10%
Threshold value
set as a relative
value
rates of machines. The ATC function is especially
effective for the applications that require high-
resolution detection.
ON
Output
OFF
Malfunction Adjustment is required
Time
Threshold value is corrected every 30 seconds *
Malfunctions are prevented
ON
Output
OFF
Time
* Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition range.