English
Language : 

X-10G Datasheet, PDF (4/8 Pages) Omron Electronics LLC – General-purpose Basic Switch
Note: 1. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number
2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions.
Pin Plunger
X-10G-B
PT
OP
4.2
+0.075
-0.025
Short Spring Plunger
X-10GD-B
PT
OP
23.3±0.25
4.2
+0.075
-0.025
dia.
hole
2.3 dia.
2.3SR *1
*2
4.36
+0.1
-0.05
dia.
25.4±0.1
11.9
49.2
24.2
9.2
17.45±0.2
*1. Stainless-steel pin plunger
*2. Three vent holes
23.3±0.25
12SR *1
12.3 dia.
10 dia.
7.15 dia.
*2
24.2
Slim Spring Plunger
X-10GS-B
PT
23.3±0.25
*1
OP
9 dia.
5.2 dia.
4 dia.
*2
24.2
*1. Stainless-steel pin plunger (flat, 1R chamfering)
*2. Three vent holes
Panel Mount Plunger
X-10GQ-B
PT
OP
13.1 *3
16.3
23.3±0.25
11.9SR
*1
16 dia.
8.35 dia.
M12 x 1 mounting screw
Two hexagonal nuts
(2 t x 14 width
across flats)
Two lock nuts
(2 t x 15.6 width
across flats)
*2
Panel Mount Roller Plunger
X-10GQ22-B
PT
23.3 ±0.25
OP
15.5 *3
16.3
16 dia.
*1. Plated iron plunger
*2. Three vent holes
12.7 dia. x 4.8 *1
*1. Stainless-steel pin plunger
*2. Three vent holes
*3. Incomplete screw part with a maximum length of 1.5 mm.
Note: Do not use both the M12 mounting screw and the mounting holes in the
case at the same time. Doing so will cause stress to be applied to the
Switch, possibly damaging the case or cover.
Panel Mount Cross Roller Plunger
X-10GQ21-B
PT
23.3±0.25
12.7 dia. x 4.8 *1
M12 x 1 mounting screw
Two hexagonal nuts
(3 t x 17 width
across flats)
*2
OP
15.5 *3
16.3
16 dia.
M12 x 1 mounting screw
Two hexagonal nuts
(3 t x 17 width
across flats)
*2
*1. Stainless-steel roller
*2. Three vent holes
*3. Incomplete screw part with a maximum length of 1.5 mm.
Note: Do not use both the M12 mounting screw and the mounting holes in the
case at the same time. Doing so will cause stress to be applied to the
Switch, possibly damaging the case or cover.
*1. Stainless-steel roller
*2. Three vent holes
*3. Incomplete screw part with a maximum length of 1.5 mm.
Note: Do not use both the M12 mounting screw and the mounting holes in the
case at the same time. Doing so will cause stress to be applied to the
Switch, possibly damaging the case or cover.
Leaf Spring
X-10GL-B
FP OP
49.6±0.8
t = 0.3 *1
4.8
*2
*1. Stainless-steel spring lever
*2. Three vent holes
Operating Characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
FP max.
OP
X-10G-B
510 gf
114 gf
0.9 mm
0.13 mm
0.18 mm
−
15.9±0.4 mm
X-10GS-B
510 gf
114 gf
0.9 mm
1.6 mm
0.18 mm
−
28.2±0.5 mm
* Be sure to use the switch at the rated OT value of 1.6 mm.
X-10GD-B
510 gf
114 gf
0.9 mm
1.6 mm
0.18 mm
−
21.2±0.5 mm
X-10GQ-B
510 gf
114 gf
0.9 mm
5.5 mm
0.18 mm
−
21.8±0.8 mm
X-10GQ22-B
510 gf
114 gf
0.9 mm
3.6 mm
0.18 mm
−
33.4±1.2 mm
X-10GQ21-B
510 gf
114 gf
0.9 mm
3.6 mm
0.18 mm
−
33.4±1.2 mm
X-10GL-B
200 gf
14 gf
−
1.6 mm *
2.3 mm
22.1 mm
17.4±0.8 mm
144
General-purpose Basic Switch X