English
Language : 

X-10G Datasheet, PDF (2/8 Pages) Omron Electronics LLC – General-purpose Basic Switch
Specifications
■ Characteristics
Operating speed
Operating frequency
Contact resistance
Insulation resistance
Dielectric strength
Mechanical
Electrical
Vibration resistance
Malfunction
Shock resistance
Destruction
Malfunction
Degree of protection
Degree of protection against electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Service life
Mechanical
Electrical
Weight
0.1 mm to 1 m/s (See note 1)
240 operations/min
20 operations/min
15 mΩ max. (initial value)
100 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between
current-carrying metal parts and the ground, and between each terminal and
non-current-carrying metal parts
10 to 55 Hz, 1.5-mm double amplitude (See note 2)
1,000 m/s2 max.
300 m/s2 max. (See notes 1 and 2)
IP00
Class I
175
−25°C to 80°C (with no icing)
35% to 85%RH
1,000,000 operations min.
100,000 operations min.
Approx. 27 to 63 g
Note: 1. The values are for the pin plunger models.
2. Malfunction: 1 ms max.
■ Ratings
Rated
voltage
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
10
3
1.5
10
3
1.5
10
3
1.5
10
3
1.5
3
1.5
0.75
Note: 1. The above values are for the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-
state current.
4. Motor load has an inrush current of 6 times the steady-state
current.
Inductive load (A)
Inductive load
Motor load
NC
NO
NC
NO
10
10
5
2.5
10
10
5
2.5
10
10
5
2.5
7.5
6
5
2.5
2
1.5
2
1.5
5. The above electrical ratings also apply to the AC voltage.
6. With the reverse-type models (X-10GM@), the normally
closed circuits and normally open circuits are reversed.
7. The ratings values apply under the following test conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
■ Contact Specification
■ Safety Standards Ratings
Contacts
Material
Gap (standard value)
NC
Inrush current
NO
Silver
0.9 mm
30 A max.
15 A max.
UL/CSA
Rated voltage
125 VDC
250 VDC
EN (CE) (Conform to EN61058-1)
Rated voltage
125 VDC
X-10G
10 A
3A
X-10
10 A
142
General-purpose Basic Switch X