Engineering Data
■ Mechanical Durability (X-10G)
5,000
3,000
1,000
700
500
Ambient temperature: 20±2°C
Ambient humidity: 65±5%RH
Without load
Operating frequency: 240 operations/min
300
200
100
70
50
30
20
10
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Overtravel (mm)
■ Structure
Contact Form (SPDT)
(+) COM
NC
NO
Note: With the reverse-type models (X-10GM@), the NC and NO
terminal arrangements are reversed.
■ Electrical Durability (X-10G)
500
300
Ambient temperature: 20±2°C
Ambient humidity: 65±5%RH
200
Operating frequency: 20 operations/min
100
70
50
30
20
125 VDC
10 L/R = 7 ms
7
5
3
2
1
0
2
4
125 VDC L/R = 0
6
8
10 12 14
Switching current (A)
Dimensions
Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions.
■ Terminals
Screw Terminals (-B)
Solder Terminal (Blank)
9.2
20
20
17.45±0.2
6.4
25.4±0.1 11.9
17.45±0.2
COM
NO
NC
Three, M4 x 5.5
1
3
2
Terminal screws
(with toothed
49.2
washer)
Note: 1. Appropriate terminal screw tightening torque: 0.78 to 1.18 N·m.
2. In case of DC voltage, set the COM to the positive terminal.
3
1 NO
COM
NC
2
49.2
■ Mounting
All switches can be mounted using M4 mounting screws with plane
washers or spring washers to securely mount the Switch. Tighten the
screws to a torque of 1.18 to 1.47 N·m.
Versions with panel mount plungers can be panel mounted via the
plunger, provided that the hexagonal nut of the actuator is tightened
to a torque of 2.94 to 4.9 N·m.
Two, 4.2-dia. mounting
holes or M4 screw holes
Panel Mount Plunger
12.5
+0.2
0
dia.
Panel Mount Roller Plunger
12.5
+0.2
0
dia.
25.4±0.1
5+00.2
13+00.2
Note: Mount using either the side mounting holes or the panel mount plunger, not both. If using the side mounting holes, then remove the hexagonal nut(s)
from the panel mount plunger.
Accessories (Terminal Covers, Actuators, and Separators): Refer to ‘Z/A/X/DZ Common Accessories’ datasheet
General-purpose Basic Switch X 143