S8AS Datasheet, PDF (2/26 Pages) Omron Electronics LLC – Smart Power Supply
S8AS
Specifications
S8AS-24006@
Item
Model
S8AS-24006
S8AS-24006N
S8AS-24006R
Efficiency (Typ.)
80% min.
Voltage range *1
100 to 240 VAC (85 to 264 VAC)
Frequency *1
50/60 Hz (47 to 63 Hz)
Input
condi-
tions
Current
100-V input
200-V input
Power factor
Harmonic current
Leakage
current
100-V input
200-V input
3.8 A max.
2.0 A max.
0.95 min.
EN61000-3-2
0.5 mA max.
1.0 mA max.
Inrush current 100-V input
*2
200-V input
25 A max. (for a cold start at 25°C)
50 A max. (for a cold start at 25°C)
Number of branches
6
Maximum cutoff output current (per branch)
3.8 A
Total output current
10 A
Allowable voltage range *3
±10% (with V.ADJ)
Output
condi-
tions
Ripple noise voltage
Output leakage current
Input fluctuation
2.0% [P-P] max. (for rated input and output voltage) *4
10 mA max.
0.5% max. (Input: 85 to 264 VAC, 100% load) *5
Load fluctuation (rated input voltage)
4.0% max. (rated input, 0% to 100% load) *5
Temperature fluctuation
0.05%/°C max.
Startup time *2
3,000 ms max. (for rated input and output voltage) *4
Output hold time *2
20 ms max. (for rated input and output voltage) *4
Abnormal voltage tripping
28.8 V (Cannot be changed.)
Tripping
functions
Abnormal current tripping *2
Abnormal total current tripping
Setting range: 0.5 to 3.8 A
(in 0.1-A increments)
3.8 A (Cannot be changed.)
Setting range: 0.5 to 3.8 A
(in 0.1-A increments)
Branch outputs are cut off when the total output current is more than 17 A for 2 s, 15 A for 5 s, 13 A for 10 s, or 12 A for 20 s.
Tripping alarm output
Photoswitch output
30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max.
Undervoltage Undervoltage detection
detection
functions
Undervoltage detection output
Setting range: 18.0 to 26.4 V
(in 0.1-V increments)
20.0 V (Cannot be changed.)
Setting range: 18.0 to 26.4 V
(in 0.1-V increments)
Photoswitch output
30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max.
Maintenance
forecast
monitor
function
Maintenance forecast monitor
Maintenance forecast monitor
output
Setting range: 0.0 to 5.0 yr
(in 0.5-yr increments)
0.5 yr (Cannot be changed.)
Setting range: 0.0 to 5.0 yr
(in 0.5-yr increments)
Photoswitch output
30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max.
Over-
temperature
detection
function
Over-temperature
Over-temperature output
Setting range: 25 to 90°C
(in 1°C increments)
90°C (Cannot be changed.)
Setting range: 25 to 90°C
(in 1°C increments)
Photoswitch output
30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max.
Output voltage display
Display range:17.0 to 30.0 V
Display accuracy: 2% rdg ±1 digit max.
Func-
tions
Display
functions
Output current display
Maintenance forecast monitor
display
Branch output display range: 0.0 to 4.0 A
Peak output current display range: 0.0 to 20.0 A
Total current display range: 0.0 to 40.0 A
Display accuracy: 5% FS (4 A) ±1 digit max.
Display range: FUL (Full)/HLF (Half)/0.0 to 5.0 yr
Temperature display
Display range: −20 to 100°C
Display accuracy: 2°C ±1 digit max.
External Tripping Input
The input can be enabled or disabled for
each branch output.
19.2 to 30.0 VDC, minimum signal
width: 10 ms, tripping after input within
20 ms + the shutdown sequence set
time
All branch outputs: Enabled
(Cannot be changed.)
19.2 to 30.0 VDC, minimum signal
width: 10 ms, tripping after input within
20 ms + the shutdown sequence set
time
The input can be enabled or disabled for
each branch output.
19.2 to 30.0 VDC, minimum signal
width: 10 ms, tripping after input within
20 ms + the shutdown sequence set
time
Startup sequence
Setting range: 0.0 to 99.9 s in 0.1-s
increments
Branch output 1: 0.0 s
(Cannot be changed.)
Branch output 2: 0.4 s
(Cannot be changed.)
Branch output 3: 0.8 s
(Cannot be changed.)
Branch output 4: 1.2 s
(Cannot be changed.)
Branch output 5: 1.6 s
(Cannot be changed.)
Branch output 6: 2.0 s
(Cannot be changed.)
Setting range: 0.0 to 99.9 s in 0.1-s
increments
Shutdown sequence
Setting range: 0.0 to 99.9 s in 0.1-s
increments
All branch outputs: 0.0 s
(Cannot be changed.)
Setting range: 0.0 to 99.9 s in 0.1-s
increments
Communications
Not supported
Supported (RS-485)
Sampling period
1 ms
Parallel connection
Not supported
Series connection
Not supported
Note: Refer to the next page for information on *1 to *5.