I/O Circuit Diagrams
E2E-X@D@ DC 2-Wire Models
Operation
mode
Model
Timing Chart
E2E
Output circuit
E2E-X@D1-N
E2E-X@D1-M1G(J)
E2E-X@D1-(M1TGJ)-U
E2E-X@D1-M3G
Without
self-
diagnostic
output:
NO
E2E-X@D1-M1J-T
Unstable
Non-sensing sensing
area
area
Set position
Stable sensing area
Proximity Sensor
Sensing
object
(%)
100 80
Rated
sensing
distance
0
ON
Setting indicator
OFF (green)
ON
Operation
OFF indicator (red)
ON
Control output
OFF
Without
self-
diagnostic
output:
NC
E2E-X@D2-N
E2E-X@D2-M1G
E2E-X@D2-(M1TGJ)-U
E2E-X@D2-M3G
Non-sensing
area
Sensing area
Sensing
object
(%)
100
Rated
sensing
distance
Proximity Sensor
0
ON
OFF
Operation
indicator (red)
ON
OFF Control output
Polarity: Yes
Prox-
imity
Sensor
main
circuit
1
Load
Brown
+V
4
Blue
0V
Note: The load can be connected to either the
+V or 0 V side.
Polarity: None
Prox-
imity
Sensor
main
circuit
4
Load
+V
(0 V)
3
0V
(+V)
Note 1. The load can be connected to either the +V or
0 V side.
2. The E2E-X@D1-M1J-T has no polarity.
Therefore, terminals 3 and 4 have no polarity.
Prox-
imity
Sensor
main
circuit
1
Load
Brown
+V
2
Blue
0V
Note: The load can be connected to either the +V
or 0 V side.
With self-
diagnostic
output:
NO
E2E-X@D1S
E2E-X@D1S-M1
Non-sensing
area
Unstable
sensing
area
Set position
Stable sensing area
Proximity Sensor
Sensing
object
(%)
100 80
Rated
sensing
distance
0
ON
OFF Setting indicator
ON (green)
OFF Operation
ON indicator (red)
OFF Control output
ON
OFF Diagnostic output*
* The diagnostic output is ON when there is a coil
burnout or the sensing object is located in the
unstable sensing area for 0.3 s or longer.
Prox-
imity
Sensor
main
circuit
Brown (4)
Load
+V
Load
+V
Orange (2)
(diagnostic
output)
Blue (3)
0
Note: Connect both the loads to the +V side of
the control output and diagnostic output.
19