English
Language : 

E2EX1R5E1 Datasheet, PDF (11/35 Pages) Omron Electronics LLC – Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
Ratings and Specifications
E2E
E2E-X@D@ DC 2-Wire Models
Size
M8
M12
M18
M30
Shielded Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Item
Model E2E-X2D@
E2E-X4MD@ E2E-X3D@
E2E-X8MD@ E2E-X7D@
E2E-X14MD@ E2E-X10D@ E2E-X20MD@
Sensing distance
2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Set distance *1
0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm
0 to 16 mm
Differential travel
15% max. of sensing distance 10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 16 and 17.
Standard sensing
object
Iron,
8 × 8 × 1 mm
Iron,
20 × 20 × 1 mm
Iron,
12 × 12 × 1 mm
Iron,
30 × 30 × 1 mm
Iron,
18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron,
54 × 54 × 1 mm
Response frequency
*2
1.5 kHz
1 kHz
0.8 kHz
0.5 kHz
0.4 kHz
0.1 kHz
Power supply voltage
(operating voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
range)
Leakage current
0.8 mA max.
Control
output
Load
current
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
Residual
voltage 3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
*3
Indicators
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 19 for details.
Diagnostic output
delay
0.3 to 1 s
Protection circuits
Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient
temperature range
Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient
humidity range
Operating/storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance
at 23°C in the temperature range ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
of −25 to 70°C
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Pre-wired
Models
Weight
(pack-
ed
state)
Pre-wired
Connector
Models
Connector
Models
Approx. 60 g
---
Approx. 15 g
Approx. 70 g
Approx. 40 g
Approx. 25 g
Approx. 130 g
Approx. 70 g
Approx. 40 g
Approx. 175 g
Approx. 110 g
Approx. 90 g
Case
Stainless steel (SUS303)
Nickel-plated brass
Materi-
als
Sensing sur-
face
Clamping
nuts
PBT
Nickel-plated brass
Toothed
washer
Zinc-plated iron
Accessories
Instruction manual
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 26 for
details.)
11