English
Language : 

E2EX1R5E1 Datasheet, PDF (13/35 Pages) Omron Electronics LLC – Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
E2E
E2E-X@T1 AC/DC 2-Wire Models
Size
M12
M18
M30
Shielded
Shielded
Item
Model
E2E-X3T1
E2E-X7T1
E2E-X10T1
Sensing distance
3 mm ±10%
7 mm ±10%
10 mm ±10%
Set distance
0 to 2.4 mm
0 to 5.6 mm
0 to 8 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 16.)
Standard sensing object Iron, 12 × 12 × 1 mm
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Response DC
frequency *1 AC
1 kHz
25 Hz
0.5 kHz
0.4 kHz
Power supply voltage
24 to 240 VDC (20 to 264 VDC)
(operating voltage range) *2 48 to 240 VAC (40 to 264 VAC)
Leakage current
DC: 1 mA max.
AC: 2 mA max.
Control
output
Load
current
Residual
voltage
5 to 100 mA
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Indicators
Operation indicator (red), Setting indicator (green)
Operation mode
(with sensing object
approaching)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
Protection circuits
Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Ambient temperature range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 80 g
Approx. 140 g
Approx. 190 g
Case
Nickel-plated brass
Materials
Sensing
surface
Clamping
nuts
PBT
Nickel-plated brass
Toothed
washer
Zinc-plated iron
Accessories
Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
13