AC Timing Diagrams (Continued)
10086831
FIGURE 3. “16 Grayscale” Test Pattern - DS90C365 (Notes 8, 9, 10)
Note 7: The worst case test pattern produces a maximum toggling of digital circuits, LVDS I/O and CMOS/TTL I/O.
Note 8: The 16 grayscale test pattern tests device power consumption for a “typical” LCD display pattern. The test pattern approximates signal switching needed
to produce groups of 16 vertical stripes across the display.
Note 9: Figures 1, 2 show a falling edge data strobe (TxCLK IN/RxCLK OUT).
Note 10: Recommended pin to signal mapping. Customer may choose to define differently.
10086830
FIGURE 4. DS90C385/DS90C365 (Transmitter) LVDS Output Load
10086806
FIGURE 5. DS90C385/DS90C365 (Transmitter) LVDS Transition Times
www.national.com
6