English
Language : 

PXI-5404 Datasheet, PDF (5/6 Pages) National Instruments Corporation – 9 kHz to 105 MHz sine wave/DC to 100 MHz clock/1.07 μHz frequency resolution
100 MHz Frequency Generator
Specifications (continued)
Physical
Dimensions ................................................ 16.0 by 10.0 cm
(1 3U PXI Slot)
(6.3 by 3.9 in.)
I/O Panel Connectors
CH0 SINE ............................................ SMB male
CH0 CLOCK.......................................... SMB male
PFI 0 .................................................... SMB male
REF IN .................................................. SMB male
REF OUT .............................................. SMB male
I/O Panel Indicators
Access LED .......................................... Off: Not ready
Green: Ready to be accessed by software
Amber: Accessed by computer
or controller
Active LED............................................ Off: Disabled or in a stopped state
Red: Error (PLL unlocked or software
detected an error)
Green: Generating a waveform
Amber: Waiting for a trigger
Environment
Operating Temperature.............................. 0 to 50 ˚C
Storage Temperature ................................ -20 to 70 ˚C
Notes
1. Output voltage amplitudes assume a 50 Ω load, unless otherwise noted.
2. SINE output voltage amplitude set to 2 Vpp, unless otherwise noted. Load of
50 Ω unless otherwise noted.
3. CLOCK level set to 5 V, unless otherwise noted.
4. Typical specifications are determined on a small sampling of PXI-5404 modules.
5. Guaranteed by Design specifications are not tested in production.
6. 100% tested specifications are measured on every unit.
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 5