English
Language : 

PTGL09BD2R2N2B51B0 Datasheet, PDF (62/103 Pages) Murata Manufacturing Co., Ltd. – PTC Thermistors for Overcurrent Protection / for Inrush Current Suppression / for Overheat Sensing Lead Type
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
c Operating Time 250V Series (Typical Curve)
PTGL07BB220N0B52A0
40
30
20
–10°C
10
25°C Ambient Temp.
60°C
0.5
1.0
1.5
Overcurrent (A)
PTGL10BB120N0P52A0
70
60
50
–10°C
25°C Ambient Temp.
40
60°C
30
20
10
0
0
0.5
1.0
1.5
Overcurrent (A)
PTGL09AR390N0B52A0
R90E.pdf
Sep.24,2012
30
–10°C
25°C Ambient Temp.
60°C
20
9
10
0
0
0.5
1.0
1.5
2.0
Overcurrent (A)
c Operating Time 265V Series (Typical Curve)
PTGL05AR151H8P52B0
70
60
50
40
30
–10°C
25°C Ambient Temp.
60°C
20
10
00
0.04
0.08
0.12
0.16
0.20
Overcurrent (A)
60
PTGL05AR181M9N51B0
25
20
15
–10°C
25°C Ambient Temp.
60°C
10
5
0
0
0.2
0.4
0.6
0.8
Overcurrent (A)
Continued on the following page.