PERFORMANCE DATA: OUTPUT VOLTAGE = 0.8 VOLTS
Efficiency vs. Line Voltage and Load Current @ +25°C (VIN = 12V)
87
82
77
72
VIN = 14 V
VIN = 12 V
VIN = 6 V
67
62
57
52
47
42
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Output Current (Amps)
LSM2-T/30-D12R Maximum Current Temperature Derating
(VIN= 12V, Transverse Airflow). Extra ground pads installed.
31.00
30.00
29.00
300 LFM
400 LFM
28.00
27.00
26.00
25.00
24.00
23.00
Natural Convection
22.00
21.00
100 LFM
20.00
200 LFM
19.00
18.00
17.00
16.00
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (°C)
LSM2-T/30-D12 Series
DOSA-SMT, 30A POL DC/DC Converters
Output Ripple & Noise (VIN = 12 V, IOUT = 30 A,
COUT = 10μF || 1μF, ’scope BW = 20 MHz)
Power-On Startup (VIN = 12 V, IOUT = 30 A)
StepLoad Transient Response (VIN = 12 V, 0-15A-0)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
www.murata-ps.com/support
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
MDC_LSM2_T30_D12 Series.C01Δ Page 12 of 12